Important Grounding Information

The following information is intended to help you understand when to use the grounding wire and clamp
provided with your sprayer.
Please read the information on the material container label to determine if it is oil-based or flammable. Ask
for a Safety Data Sheet (SDS) from your supplier. The container label and SDS will explain the contents of
the material and the specific precautions related to it.
Paints, coatings and clean-up materials generally fit into one of the following 3 basic types:
Grounding
Wire and
Clamp
Required?
No
Yes
Yes
NOTE: To spray flammable materials, you must install the Lacquer Conversion Kit, page 32.
3A9019A EN
Important Grounding Information
WATER-BASED: The container label should indicate that the material
can be cleaned up with soap and water.
OIL-BASED: The container label should indicate that the material is
COMBUSTIBILE and can be cleaned up with mineral spirits or
non-flammable paint thinner. Use oil-based material outdoors or in a
well-ventilated indoor area with a flow of fresh air. See the safety
warnings in this manual. Follow Grounding Instructions, page 11, when
using this type of material.
FLAMMABLE: This type of material contains flammable solvents such
as xylene, toluene, naphtha, MEK, lacquer thinner, acetone, denatured
alcohol, and turpentine. The container label should indicate that this
material is FLAMMABLE. Use flammable materials outdoors or in a
well-ventilated area with a flow of fresh air. Follow Grounding
Instructions, page 11, when using this type of material.
Type of Material
5