Acceptance Quality Level
When a critical defect is found, this must be reported immediately upon detection, the lot
or batch shall be rejected and further shipments shall be held up pending instructions
from the responsible person in relevant organization.
Major Defective: 0.4 AQL
Minor Defective: 1.50 AQL
3.2.9.
GENERAL RULES
The inspection must be carried out by trained inspectors having good knowledge of the
meaning of "fitness for use". The inspection must be based upon the documents
concerning the completely assembled and packed product when more defects appear
with the same cause only the most serious defect must be taken into account. Defects
found in accessories packed with the product as connecting cables, plugs, adapters and
the like, and being inspected as a part of the complete product, must be included in the
evaluation.
The evaluation must be within the limits of the product specification and, for not specified
characteristics, be related to the design model, limit samples or judgment of a jury of
experts.
Faults must be demonstrable.
3.2.10.
TEST CONDITIONS
Unless otherwise prescribed, the test conditions are as follows:
. Nominal mains voltage
. Temperature: +5~+35℃
. Warm up time: 30minutes minimum.
. Visual inspection shall be down with the distance from eyes to the sample 35-50 cm.
. Display mode: Primary mode 1366*768
3.2.11.
TEST EQUIPMENTS
1. PC with display adapter or other specific display adapter which is agreed
upon by both parties
2. Test program by BenQ
3. Ruler
4. Power saving test tool
5. Minolta color analyzer (CA-110 or BM – 7)