Nokia Customer Care
levels may differ from target power levels mentioned in Phoenix.
Press "Save and Continue" and TX Power Level Tuning is finished.
Auto-Tune with Phoenix
Automatic tuning for RH-29 RF parameters is possible. Auto-Tune tunes all RF parame-
ters for both of the bands.
Needed equipment
PC running Nokia Phoenix SW
Test jig MJ-21
Power source
Cables: RF-cables for measurements and GPIB-cable(s) to control test
equipment
R&S CMU200
OR one TX- and one RX-equipment and RF-splitter:
TX:
Agilent E4406 (VSA series transmitter tester)
Agilent E4445 (PSA series transmitter tester)
Rohde&Schwarz, FSE-family of Signal Analyzers
Rohde&Schwarz, FSIQ-family of Signal Analyzers
RX:
Agilent ESG family of RF Signal Generators
Rohde&Schwarz, SME-family of Signal Generators
Set Loss
Path losses caused by test jig MJ-21 and RF-cables must be set correctly before tuning.
To be able to change these values, there have to be some phone connected to Phoenix.
Select right connection type from Phoenix and set operating mode to local mode.
Select