RH-29
6b - RF Troubleshooting
Select
Wait until the RF Controls window pops up
Select
Select
The setup should now look like this:
Apply a signal with a frequency of
EGSM900: 942.467 MHz (channel 37 + 67.710kHz offset)
GSM1800: 1842.867 MHz (channel 700 +67.710kHz offset)
and a power level of -80dBm to the RF-connector (remember to compensate for cable
attenuation).
In RSSI reading click Start.
Page 10
Company Confidential
Testing
RF Controls
Band
Active unit
Operation mode
RX/TX Channel
Testing
RSSI reading