RX AGC limits
The Rx calibration is only valid if it is within certain limits.
For the most recent limits see RH-29 Production Testing Requirements,
If calibration is not within limits, there is a fault in the RX chain.
Below the values for RSSI4 and RSSI7 are given:
RSSI4:
band
min
EGSM900
81
DCS1800
79
RSSI7:
band
min
EGSM900
103
DCS1800
100
RX band filter response compensation
EGSM900 and DCS1800
Set operating mode to local mode
Select
Issue 1 05/2004
Company Confidential
Table 2:
typ
86
85
Table 3:
typ
108
104
Tuning
RX Band Filter Response Compensation
Select
Copyright © 2004 Nokia Corporation
Company Confidential
6b - RF Troubleshooting
max
91
89
max
113
110
Band
EGSM900
RH-29
Alt-u
B
Page 19