Rx Agc Limits; Rx Band Filter Response Compensation; Egsm900; Dcs1800 - Nokia RH-29 Series Manual

Table of Contents

Advertisement

Nokia Customer Care

RX AGC limits

The Rx calibration is only valid if it is within certain limits.
For the most recent limits see RH-29 Production Testing Requirements,
If calibration is not within limits, there is a fault in the RX chain.
Below the values for RSSI4 and RSSI7 are given:
RSSI4:
band
min

EGSM900

81

DCS1800

79
RSSI7:
band
min
EGSM900
103
DCS1800
100

RX band filter response compensation

EGSM900 and DCS1800
Set operating mode to local mode
Select
Issue 1 05/2004
Company Confidential
Table 2:
typ
86
85
Table 3:
typ
108
104
Tuning
RX Band Filter Response Compensation
Select
Copyright © 2004 Nokia Corporation
Company Confidential
6b - RF Troubleshooting
max
91
89
max
113
110
Band
EGSM900
RH-29
Alt-u
B
Page 19