3.1.3 Initial startup via the serial interface

Note
The serial interface should only be used for initial startup if this is not possible via a
LAN port.
Prerequisite
The SLIP connection in the dial-up network must be installed separately from the op-
erating system.
Step
1.
Connect the serial interface cable (S30122-X5468-X3).
2.
Install Assistant Xpress @LAN/HG 1500.
3.
Configure the IP address (1.0.0.2) of the PC (SLIP)
4.
From the DOS command window, ping HiPath HG 1500
(IP 1.0.0.1).
5.
Generate an empty customer database and load to HiPath HG 1500.
6.
Save and administer customer data.
Note
The SLIP configuration on the PC is described in detail in the Administration Docu-
ments Hicom 150 E Office for HiPath HG 1500.
A31003-K5020-S100-6-7620
Service Manual
Initial startup of HiPath HG 1500
Task
lan2de.c03
Startup
3-3