DESCRIPTION
Series 8323G0XX, and 8323G3XX are 3-way redundant dual
solenoid-operated pilot valves designed for instrument air
service. Valves are normally closed or normally open depending
upon requirements.
Series 8323G0XX valves are supplied with a general purpose or
a explosionproof/watertight solenoid enclosures.
Series 8323G3XX valves are provided with low power general
purpose solenoid enclosures.
Operation Identification Chart
(Operation vs Catalog Number)
Operation
Catalog Number / Construction
8323G052 / Stainless Steel
Normally Closed
(See Note)
8323G352 / Stainless Steel
8323G053 / Stainless Steel
Normally Open
(See Note)
8323G353 / Stainless Steel
NOTE: Normally closed pilot valves are used on ASCO no-
voltage release manual reset valves; normally open pilot valves
are used on trip shut-off manual-reset valves.
OPERATION
Normally Closed (Pressure at Port 3)
Both Solenoids De-energized: Flow is from Port 1 to Pilot
Exhaust.
Either or Both Solenoids Energized: Flow is from Port 3 to
Port 1.
Page 1 of 4
E316582 - 08/2021
No. 57, Kundrathur Main Rd., Gerugambakkam, Chennai - 6000128, India
NORMALLY CLOSED AND NORMALLY OPEN OPERATION
BRASS AND/OR STAINLESS STEEL CONSTRUCTION
1/4" NPT – INSTRUMENT AIR SERVICE
solenoid
installation
8323G051 / Brass
8232G351 / Brass
and
Normally Open (Pressure at Solenoid Pilot)
Both Solenoids De-energized: Flow is from Pilot Press to Port
1.
Either or Both Solenoids Energized: Flow is from Port 1 to
Port 3.
Check nameplate for correct catalog number, pressure, voltage,
frequency, and service. Never apply incompatible fluids or
exceed pressure rating of the valve. Installation and valve
maintenance to be performed by qualified personnel.
Future Service Considerations
Provision should be made for performing seat leakage, external
leakage, and operational tests on the valve with a non-hazardous,
non-combustible fluid after disassembly and reassembly.
Temperature Limitations
For valve fluid and ambient temperature ranges, refer to chart
below. Check catalog number on nameplate.
Catalog Number Fluid & Ambient Temperature Range
8323G051
8323G052
8323G053
8323G351
8323G352
8323G353
Positioning
Valve may be mounted in any position.
Mounting
Refer to Figure l, for valve body mounting dimensions.
All Rights Reserved.
IM-IND-553130-RevAA
SERIES
8323G0XX
8323G3XX
INSTALLATION
AC Service
32 °F (0 °C) to 125 °F (52 °C)
DC Service
32 °F (0 °C) to 104 °F (40 °C)
-40 °F (-40 °C) to 140 °F (60 °C)
IM-IND-553130-RevAA
www.emerson.com

Advertisement

loading

Summary of Contents for Emerson 8323G0 Series

  • Page 1 Positioning Valve may be mounted in any position. Mounting Refer to Figure l, for valve body mounting dimensions. IM-IND-553130-RevAA Page 1 of 4 All Rights Reserved. E316582 - 08/2021 No. 57, Kundrathur Main Rd., Gerugambakkam, Chennai - 6000128, India www.emerson.com...
  • Page 2 IM-IND-553130-RevAA Page 2 of 4 All Rights Reserved. No. 57, Kundrathur Main Rd., Gerugambakkam, Chennai - 6000128, India www.emerson.com...
  • Page 3 Figure 2. Redundant Pilot Operator Assembly - Series 8323G051 and 8323G052 Figure 3. Redundant Pilot Operator Assembly - Series 8323G053 Figure 4. Redundant Pilot Operator Assembly - Series 8323G351 and 8323G352 IM-IND-553130-RevAA Page 3 of 4 All Rights Reserved. No. 57, Kundrathur Main Rd., Gerugambakkam, Chennai - 6000128, India www.emerson.com...
  • Page 4 Figure 5. Redundant Pilot Operator Assembly - Series 8323G353 IM-IND-553130-RevAA Page 4 of 4 All Rights Reserved. No. 57, Kundrathur Main Rd., Gerugambakkam, Chennai - 6000128, India www.emerson.com...

This manual is also suitable for:

8323g3 series8323g0518323g0528232g3518323g3528323g053 ... Show all