Ceiling concealed chilled water fan coil unit
Hide thumbs Also See for C Series:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
‫ﺑﻴﺎﻥ ﺍﳋﻄﺄ‬
E1
E2
E6
E5
Th °C / °F
Ts °C / °F
-
15.0 / 59.0
-
27.0 / 80.6
.‫ﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ ﺍﻟﺒﺼﻴﻠﺔ ﺍﻟﺮﻃﺒﺔ‬
: Th
‫ﻗﻢ ﺑﺈﺟﺮﺍﺀ ﺍﺧﺘﺒﺎﺭ ﻋﻠﻰ ﺍﻟﻮﺣﺪﺓ ﺑﻌﺪ ﺇﺟﺮﺍﺀ ﺍﺧﺘﺒﺎﺭ ﺻﺮﻑ ﺍﻟﻤﻴﺎﻩ‬
‫ﻫﻞ ﺗﻢ ﺍﺩﺧﺎﻝ ﺍﻟﻘﺎﺑﺲ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ ﺑﺼﻮﺭﺓ ﻛﺎﻣﻠﺔ ﻓﻲ ﺍﻟﻤﻘﺒﺲ؟‬
‫ﻫﻞ ﺗﺼﺪﺭ ﺍﺻﻮﺍﺕ ﻏﻴﺮ ﻋﺎﺩﻳﺔ ﻣﻦ ﺍﻟﻮﺣﺪﺓ؟‬
‫ﻫﻞ ﻳﻮﺟﺪ ﺍﻫﺘﺰﺍﺯ ﻏﻴﺮ ﻋﺎﺩﻱ ﻣﻦ ﺍﻟﻮﺣﺪﺓ ﻧﻔﺴﻬﺎ ﺍﻭ ﺍﻻﻧﺎﺑﻴﺐ؟‬
‫ﻫﻞ ﻳﺘﻢ ﺗﺼﺮﻳﻒ ﺍﻟﻤﺎﺀ ﺑﺼﻮﺭﺓ ﺳﻬﻠﺔ؟‬
.‫ﺩﻭﺭﺍﻥ ﻧﻔﺎﺥ ﺍﻟﻤﺒﺨﺮ ﻭﺗﻔﺮﻳﻎ ﺍﻟﻬﻮﺍﺀ ﺍﻟﺒﺎﺭﺩ‬
‫ﺍﻥ ﺩﻟﻴﻞ ﺍﻟﺘﺮﻛﻴﺐ ﺍﻟﻤﻮﺟﻮﺩ ﻓﻮﻕ ﺍﻻﻏﻄﻴﺔ ﺧﺎﺹ ﺑﻮﺣﺪﺓ ﺍﻟﻤﻠﻒ ﺍﻟﻤﺮﻭﺣﻲ ﻓﻘﻂ. ﻟﺘﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ )ﺍﻟﻤﺒﺮﺩﺓ ﺍﻟﺼﻐﻴﺮﺓ...ﺍﻟﺦ( ﻳﺮﺟﻰ ﺍﻟﺮﺟﻮﻉ ﺍﻟﻰ‬
‫ﺍﻟﻤﺪﺓ‬
‫ﻣﺮﺓ ﻭﺍﺣﺪﺓ ﻛﻞ ﺍﺳﺒﻮﻋﻴﻦ‬
‫ﺍﺯﻝ ﺍﻱ ﻏﺒﺎﺭ ﻣﻠﺘﺼﻖ ﺑﺎﻟﻤﺮﺷﺢ ﺑﺎﺳﺘﻌﻤﺎﻝ ﻣﻜﻨﺴﺔ ﻛﻬﺮﺑﺎﺋﻴﺔ ﺍﻭ ﻧﻈﻔ ﹼ ﻪ ﺑﻤﺎﺀ ﺩﺍﻓﻲﺀ ﻗﻠﻴ ﻼ ﹰ‬
.‫ﻋﻠﻰ ﺍﻻﻗﻞ‬
.‫ﺯﻳﺎﺩﺓ ﺍﻟﺘﻜﺮﺍﺭ ﻋﻨﺪ ﺍﻟﻀﺮﻭﺭﺓ‬
‫ﻣﺮﺓ ﻭﺍﺣﺪﺓ ﻛﻞ ﺍﺳﺒﻮﻋﻴﻦ‬
‫ﻧﻈ ﹼ ﻒ ﺍﯾﺔ ﺍﻭﺳﺎﺥ ﺍﻭ ﻏﺒﺎﺭ ﻳﻮﺟﺪ ﻋﻠﻰ ﺍﻟﺸﺒﻴﻜﺔ ﺍﻭ ﺍﻟﻠﻮﺣﺔ ﺑﻤﺴﺤﻪ ﺑﻘﻄﻌﺔ ﻗﻤﺎﺵ ﻧﺎﻋﻤﺔ‬
.‫ﻋﻠﻰ ﺍﻻﻗﻞ‬
.‫ﺯﻳﺎﺩﺓ ﺍﻟﺘﻜﺮﺍﺭ ﻋﻨﺪ ﺍﻟﻀﺮﻭﺭﺓ‬
.‫ﻻﺗﺸﻐ ﹼ ﻞ ﺍﻳﺔ ﺍﺟﻬﺰﺓ ﺣﺮﺍﺭﻳﺔ ﺑﺎﻟﻘﺮﺏ ﻣﻦ ﻭﺣﺪﺓ ﻣﻜﻴﻔﺔ ﺍﻟﻬﻮﺍﺀ. ﻫﺬﺍ ﺳﻮﻑ ﻳﺆﺩﻱ ﺍﻟﻰ ﺍﺫﺍﺑﺔ ﺍﻟﻠﻮﺣﺔ ﺍﻟﺒﻼﺳﺘﻴﻜﻴﺔ ﺍﻭ ﺗﺸﻮﻫﻬﺎ ﻛﻨﺘﻴﺠﺔ ﻟﻠﺤﺮﺍﺭﺓ ﺍﻟﺸﺪﻳﺪﺓ‬
‫ﺍﺿﻮﺍﺀ ﺍﻟﻤﺆﺷﺮ‬
‫ﺍﻟﺘﺒﺮﻳﺪ‬
‫ﻭﻣﻀﺔ‬
‫ﻭﻣﻀﺎﺕ‬
‫ﻭﻣﻀﺎﺕ‬
‫ﻭﻣﻀﺎﺕ‬
‫ﻣﺪﻯ ﺍﻟﺘﺸﻐﻴﻞ‬
‫ﺍﻟﺘﺪﻓﺌﺔ‬
(
‫ﻭﺿﻊ ﺍﻟﺘﺒﺮﻳﺪ‬
‫ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ‬
‫ﺍﻟﺤﺪ ﺍﻻﺩﻧﻰ‬
‫ﻟﺪﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‬
‫ﺍﻟﺤﺪ ﺍﻻﻗﺼﻰ ﻟﺪﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‬
.‫ﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ ﺍﻟﺒﺼﻴﻠﺔ ﺍﻟﺠﺎﻓﺔ‬
: Ts
‫ﺍﻟﻔﺤﺺ ﺍﻟﻌﺎﻡ‬
:‫ﺗﺠﺮﺑﺔ ﺍﻻﺧﺘﺒﺎﺭ‬
(1
.‫ﻭﺍﺧﺘﺒﺎﺭ ﺗﺴﺮﺏ ﺍﻟﻐﺎﺯ‬
:‫ﺍﻓﺤﺺ ﺍﻟﺒﻨﻮﺩ ﺍﻟﺘﺎﻟﻴﺔ‬
(2
(a
(b
(c
(d
:‫ﺗﺄﻛﺪ ﻣﻦ‬
(1
.‫ﻳﺠﺐ ﺍﻥ ﻳﺘﻢ ﺍﻟﺘﺮﻛﻴﺐ ﻣﻦ ﻗﺒﻞ ﺷﺨﺺ ﻣﺆﻫﻞ ﺍﻟﺬﻱ ﻳﻜﻮﻥ ﻋﻠﻰ ﺣﺴﻦ ﺍﻻﻃﻼﻉ ﺑﻬﺬﺍ ﺍﻟﻨﻮﻉ ﻣﻦ ﺍﻟﻤﻨﺘﺠﺎﺕ‬
‫ﺍﻟﺘﺼﻠﻴﺢ ﻭﺍﻟﺼﻴﺎﻧﺔ‬
‫ﺳﻨﻮﺍﺕ‬
‫ﺍﺟﺮﺍﺀﺍﺕ ﺍﻟﺼﻴﺎﻧﺔ‬
.‫ﻣﻊ ﻣﺤﻠﻮﻝ ﺗﻨﻈﻴﻒ ﻣﺘﻌﺎﺩﻝ‬
.‫ﺍﺷﻄﻒ ﺍﻟﻤﺮﺷﺢ ﺟﻴﺪ ﺍ ﹰ ﻭﺟﻔﻔﻪ ﻗﺒﻞ ﺍﻋﺎﺩﺓ ﻭﺿﻌﻪ ﻓﻲ ﺩﺍﺧﻞ ﺍﻟﻮﺣﺪﺓ‬
.‫ﻻﺗﺴﺘﻌﻤﻞ ﺍﻟﻜﺎﺯﻭﻟﻴﻦ، ﺍﻭ ﺍﻟﻤﻮﺍﺩ ﺍﻟﻄﻴﺎﺭﺓ ﺍﻭ ﺍﻟﻜﻴﻤﻴﺎﻭﻳﺔ ﻟﺘﻨﻈﻴﻒ ﺍﻟﻤﺮﺷﺢ‬
.‫ﻣﻊ ﻣﺤﻠﻮﻝ ﺗﻨﻈﻴﻒ ﻣﺘﻌﺎﺩﻝ‬
(
.‫ﻻﺗﺴﺘﻌﻤﻞ ﺍﻟﻜﺎﺯﻭﻟﻴﻦ ﺍﻭ ﺍﻟﻤﻮﺍﺩ ﺍﻟﻄﻴﺎﺭﺓ ﺍﻭ ﺍﻟﻜﻴﻤﻴﺎﻭﻳﺔ ﻟﺘﻨﻈﻴﻒ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‬
‫ﺗﻨﺒﻴﻪ‬
‫ﻣﺆﺷﺮ‬
LED
1
2
3
5
‫ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ‬
،
‫ﺍﻟﺘﺒﺮﻳﺪ‬
)
50 - 35
(
Th °C / °F
Ts °C / °F
14.0 / 57.2
19.0 / 66.2
23.0 / 73.4
32.0 / 89.6
.‫ﺗﺜﺒﻴﺖ ﺍﻟﻮﺣﺪﺓ ﺑﺸﻜﻞ ﻣﺘﻴﻦ ﻭﺻﻠﺐ ﻓﻲ ﺍﻟﻤﻮﻗﻊ‬
‫ﺍﻻﻧﺎﺑﻴﺐ ﻭﺍﻟﺘﻮﺻﻴﻼﺕ ﺗﻤﺖ ﺗﺠﺮﺑﺘﻬﺎ ﻭﺍﺛﺒﺎﺕ ﺧﻠﻮﻫﺎ ﻣﻦ ﺍﻟﺘﺴﺮﺏ ﺑﻌﺪ‬
‫ﺍﺳﻜﺐ ﻗﺴﻤ ﺎ ﹰ ﻣﻦ ﺍﻟﻤﺎﺀ ﻓﻲ ﺍﻟﺠﺎﻧﺐ ﺍﻻﻳﺴﺮ ﻣﻦ ﺍﻟﺤﻮﺽ‬
.(‫)ﺍﻟﺘﺼﺮﻳﻒ ﻓﻲ ﺍﻟﺠﺎﻧﺐ ﺍﻻﻳﻤﻦ ﻣﻦ ﺍﻟﻮﺣﺪﺓ‬
.‫ﻗﺪ ﻳﺨﺘﻠﻒ ﺗﺮﻛﻴﺐ ﺍﻟﻤﻠﻒ ﺍﻟﻤﺮﻭﺣﻲ ﺗﺒﻌ ﺎ ﹰ ﻟﻄﺮﺍﺯ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‬
‫ﻣﻼﺣﻈﺔ ﺻﺎﻟﺤﺔ ﻟﺘﺮﻛﻴﺎ ﻓﻘﻂ: ﻋﻤﺮ ﻣﻨﺘﺠﺎﺗﻨﺎ ﻫﻮ ﻋﺸﺮ‬
(10)
(
‫ﻣﺌﻮﻳﺔ‬
40°
‫ﻣﻨﻘﻮﻋﺔ ﺑﻤﺎﺀ ﺩﺍﻓﻲﺀ ﻗﻠﻴ ﻼ ﹰ‬
‫ﻣﺌﻮﻳﺔ‬
‫ﺍﻗﻞ ﻣﻦ‬
40°
)
!
١١
‫ﻭﺻﻒ ﺍﳋﻄﺄ‬
‫ﺧﻄﺄ ﻣﺘﺤﺴﺲ ﺍﻟﻐﺮﻓﺔ‬
‫ﺧﻄﺄ ﻣﺘﺤﺴﺲ ﻣﺎﺀ ﺍﻻﻧﺒﻮﺏ‬
‫ﺧﻄﺄ ﻣﻀﺨﺔ ﺍﳌﺎﺀ‬
‫ﻋﻄﻞ ﺣﺮﺍﺭﺓ ﻣﺎﺀ ﺍﻻﻧﺒﻮﺏ‬
:‫ﺣﺪﻭﺩ ﺍﻟﺘﺸﻐﻴﻞ‬
‫ﺍﻟﻨﺎﻗﻞ ﺍﻟﺤﺮﺍﺭﻱ: ﺍﻟﻤﺎﺀ‬
‫ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ‬
: ‫ﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ ﺍﻟﻤﺎﺀ‬
)
10 - 4
‫ﺑﺎﺭ‬
16
: ‫ﺿﻐﻂ ﺍﻟﻤﺎﺀ ﺍﻻﻗﺼﻰ‬
‫ﻛﻤﺎ ﻓﻲ ﺍﻻﺳﻔﻞ‬
: ‫ﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ ﺍﻟﻬﻮﺍﺀ‬
(
)
‫ﻭﺿﻊ ﺿﺦ ﺍﻟﺘﺪﻓﺌﺔ‬
‫ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ‬
‫ﺍﻟﺤﺪ ﺍﻻﺩﻧﻰ‬
‫ﻟﺪﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‬
‫ﺍﻟﺤﺪ ﺍﻻﻗﺼﻰ ﻟﺪﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‬
:‫ﺗﺄﻛﺪ ﻣﻦ‬
(1
(2
.‫ﺍﻟﺸﺤﻦ‬
.‫ﺗﺮﻛﻴﺐ ﺍﻻﺳﻼﻙ ﺑﺼﻮﺭﺓ ﺻﺤﻴﺤﺔ‬
(3
‫ﻓﺤﺺ ﺍﻟﺘﺼﺮﻳﻒ‬
:‫ﻣﻼﺣﻈﺔ‬
.‫ﺩﻟﻴﻞ ﺍﻟﺘﺮﻛﻴﺐ ﻟﻤﺜﻞ ﻫﺬﻩ ﺍﻟﻮﺣﺪﺓ‬
‫ﺍﻗﺴﺎﻡ ﺍﻟﺼﻴﺎﻧﺔ‬
‫ﻣﺮﺷﺢ ﺍﻟﻬﻮﺍﺀ ﺍﻟﺪﺍﺧﻠﻲ‬
.1
‫ﺍﻗﻞ ﻣﻦ‬
)
.2
.3
‫ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‬
.1
.2

Advertisement