Daikin C Series Installation Manual

Daikin C Series Installation Manual

Ceiling concealed chilled water fan coil unit
Hide thumbs Also See for C Series:

Advertisement

INSTALLATION MANUAL
CEILING CONCEALED
CHILLED WATER FAN COIL UNIT
(C Series)
IM-CCCW-0308(5)-DAIKIN (ASEAN)
Part No.: R08019031562E

Advertisement

Table of Contents
loading

Summary of Contents for Daikin C Series

  • Page 1 INSTALLATION MANUAL CEILING CONCEALED CHILLED WATER FAN COIL UNIT (C Series) IM-CCCW-0308(5)-DAIKIN (ASEAN) Part No.: R08019031562E...
  • Page 3: Outline And Dimensions

    OUTLINE AND DIMENSIONS Indoor Unit: Ceiling Concealed Fan Coil Unit C Series All dimensions are in mm LEFT PIPING WATER OUTLET WATER INLET All dimensions are in mm RIGHT PIPING WATER OUTLET WATER INLET Dimension Model FWPMM3AV1 808 774 702 741 267...
  • Page 4 All dimensions are in mm LEFT PIPING DETAIL B FOR FWPMM6/7 DETAIL A FOR FWPMM4 WATER OUTLET WATER OUTLET WATER INLET WATER INLET SEE DETAIL A FOR FWPMM4 SEE DETAIL B FOR FWPMM6/7 WATER INLET WATER OUTLET All dimensions are in mm RIGHT PIPING DETAIL A FOR FWPMM4 DETAIL B FOR FWPMM6/7...
  • Page 5 All dimensions are in mm LEFT PIPING WATER OUTLET WATER INLET All dimensions are in mm RIGHT PIPING WATER INLET WATER OUTLET Dimension Model FWPMM8AV1 FWPMM11AV1 1292 1297 1225 1264 1174 Dimension Model FWPMM8AV1 FWPMM11AV1...
  • Page 6 All dimensions are in mm LEFT PIPING WATER OUTLET WATER INLET All dimensions are in mm RIGHT PIPING WATER INLET WATER OUTLET Dimension Model FWPMM9AV1 FWPMM12AV1 1088 1105 1033 1072 FWPMM14AV1 1342 1358 1287 1326 1236 FWPMM16AV1 1542 1558 1487 1526 1436 Dimension...
  • Page 7: Safety Precautions

    INSTALLATION MANUAL This manual provides the procedures of installation to ensure a safe and good standard of operation for the air conditioner unit. Special adjustment may be necessary to suit local requirement. Before using your air conditioner, please read this instruction manual carefully and keep it for future reference. This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
  • Page 8: Installation Diagram

    INSTALLATION DIAGRAM CORK TAPE FULLY INSULATED INSULATION THROUGH OUT CHILLED WATER PIPING INSTALLATION OF THE INDOOR UNIT The indoor unit must be installed such that there is no short Center distance of axle (see drawing below) circuit of the cool discharge. Respect the installation clearance. Do not put the indoor unit where there is direct sunlight on unit.
  • Page 9: Water Piping Connection

    Ceiling Concealed Drain Piping Work Bottom of the unit Drain trap Insulate securely Unit : mm Do not leave in water • The drain pipe must be installed as shown in the diagram (see diagram above) to avoid damage caused by leaks and condensation.
  • Page 10: Electrical Wiring Connection

    ELECTRICAL WIRING CONNECTION Wire connection to the controller board is as show in the wiring diagram on the respective terminal box. HEAT Jumper VALVE Jumper Cooling Mode & Valve Application Cooling Mode & Valveless Application Heatpump Mode & Valve Application Heatpump Mode &...
  • Page 11 FWPMM3A(Z)V1 / FWPMM4A(Z)V1 / FWPMM6A(Z)V1 / FWPMM7A(Z)V1 / FWPMM8A(Z)V1 / FWPMM9A(Z)V1 / FWPMM11A(Z)V1 / FWPMM12A(Z)V1 / FWPMM14A(Z)V1 / FWPMM16A(Z)V1 (with controller) FCU 1 FCU 2 FCU 3 V ALVE V ALVE V ALVE 220-240V/1ø/50Hz or 220-240V/1ø/50Hz or 220-240V/1ø/50Hz or 208-230V/1ø/60Hz 208-230V/1ø/60Hz 208-230V/1ø/60Hz 3 way valve...
  • Page 12: Indicator Lights

    • All wires must be fi rmly connected. • Make sure all the wire do not touch the refrigerant pipings, compressor or any moving parts. • The connecting wire between the indoor unit and the outdoor unit must be clamped by using provided cord anchorage. •...
  • Page 13: Overall Checking

    OVERALL CHECKING Ensure the following, in particular:- The unit is mounted solidly and rigid in position. Piping and connections are leak proof after charging. Proper wiring has been done. Drainage check:- Pour some water into left side of drain pan (drainage are in right side of unit). Note: •...
  • Page 14 MEMO...
  • Page 16 Kita-ku, Osaka, 530-8323 Japan Tokyo offi ce: JR Shinagawa East Bldg., 2-18-1, Konan, P.O.Box 18674, Galleries 4, 11th Floor, Minato-ku, Tokyo, 108-0075 Japan Downtown Jebel Ali, Dubai, UAE. http://www.daikin.com/global/ Importer for Turkey Hürriyet Mahallesi Yakacık D-100 Kuzey Yanyol Caddesi No:49/1-2 Kartal − İstanbul...