Before Replacing the LCD / Lens Prism
You should not replace separately the parts of the liquid crystal LCD / Lens Prism because they only work properly
when used together. Therefore, regarding these parts, you can either replace the LCD / Lens Prism assembly or send
the whole LCD / Lens Prism assembly back to Hitachi, where we will replace the malfunctioning part, recondition
the device and send it back to you. Please contact our distributor.
DISTRIBUTOR
Air Filter
Cleaning the Air filter
The air filter should be cleaned as described below at intervals of approximately 300 hours.
1. Switch the projector power supply OFF, and remove the power cord from the power outlet.
2. Clean the air filter with a vacuum cleaner.
Replacing the Air filter
Replace the air filter if contamination cannot be removed, or if it is damaged.
1. Remove the filter cover.
2. Remove the old filter.
3. Set the new filter and filter cover.
CAUTION
Switch power OFF and remove the power cord from the power outlet before beginning mainte-
nance work. Please read the separate "SAFETY INSTRUCTIONS" thoroughly to ensure that
maintenance is performed correctly.
Replace the air fi lter if contamination cannot be removed, or if it is damaged. Contact your dealer
in such case. (Option Air fi lter assembly : MU01421)
Do not use the equipment with the air fi lter removed.
When the air fi lter is clogged with dust etc. the power supply is switched OFF automatically to
prevent the temperature rising inside the projector.
18
Do not disassemble the unit
because replacement of separate
parts is not possible.
For repairs of the product, please
contact our distributor.
Return
HITACHI
Replacement of G Panel
G Panel
Reconditioning

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pj750-2

Table of Contents