  • Page 1 Model: 311438113 311438115...
  • Page 2 Ambient Temperature Range for Unit Operation Choosing the Right Location Other Features Storage...
  • Page 3 personal...
  • Page 4 Your air conditioner should be used in such a way that it is protected from moisture, such as condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid. Unplug immediately if it occurs. When the water drainage function is not in use, keep the upper and the lower drain plug firmly to the unit to avoid choking.
  • Page 5 Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the presence of flammable substances or vapors, such as alcohol, insecticides, petrol, etc. Always contact a qualified person to carry out repairs. If the damaged power supply cord must be replaced with a new power supply cord, obtain it from the manufacturer.
  • Page 6 Amount Amount Compliance with national gas regulations shall be observed. Keep ventilation openings clear of obstruction. Any person who is involved with working on or breaking into a refrigerant circuit should hold a valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry-recognized assessment specification.
  • Page 7 Explanation of symbols displayed on the unit (for units that adopt R32/R290 refrigerant only): This symbol shows that information, such as the operating manual or installation manual, is available. 1. Transport of equipment containing flammable refrigerants See transport regulations 2. Marking of equipment using signs See local regulations 3.
  • Page 8 8) Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. The manufacturer's maintenance and service guidelines shall be followed at all times. If in doubt, consult the manufacturer's technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: Refrigeration pipe or components are installed in a way where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are...
  • Page 9 like recalibration that...
  • Page 10 minimize Labeling When removing refrigerant from a system, either for servicing or decommissioning, it is recommended that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available.
  • Page 11 ensure All the illustrations in the manual are for explanatory purposes only. Your machine may be slightly different. The actual shape shall prevail. The unit can be controlled by the unit control panel or with the remote controller. This manual does not include Remote Controller Operations, see the <<Remote Controller Instruction>>...
  • Page 12 Ambient Temperature Range for Unit Operation The exhaust hose and adapter must be installed or removed in accordance with the usage mode. For COOL, HEAT(heat pump type) or AUTO mode, the exhaust hose must be installed. For FAN, DRY or HEAT (electrical heat type) mode, the exhaust hose must be removed.
  • Page 13 The right air conditioner helps you cool a room efficiently. An undersized unit won't cool adequately, while one that's too large will not remove enough humidity, leaving the air feeling damp. To find the proper air conditioner, determine the square footage of the room you want to cool by multiplying the room length by its width.
  • Page 14 Adapter Adapter Adapter A Adapter B Adapter Extended Exhaust Hose Extended Exhaust Passage Adapter Step One: Preparing the Exhaust Hose Assembly Press the exhaust hose (or extended exhaust hose) into the window slider adapter (or wall exhaust adapter) and unit adapter, clamp automatically by elastic buckles of the adapters.
  • Page 15 Step Two: Install the Exhaust Hose Assembly to the Unit. Insert unit adapter of the Exhaust hose assembly into the lower groove of the air outlet of the unit while the hook of the adapter is aligned with the hole seat of the air outlet. Slide down the exhaust adapter Adapter hose assembly along the arrow direction for...
  • Page 16 NOTE: Once the exhaust hose assembly and adjustable window slider are prepared, choose from one of the following installation methods.
  • Page 17 adapter 1. Cut a 125mm (4.9inch) hole into the wall for the wall exhaust adapter B. 2. Secure the Wall Exhaust adapter B to the wall using the four anchors and screws provided in the kit. 3. Connect the exhaust hose assembly (with wall exhaust adapter A) to the Wall wall exhaust adapter B. adapter adapter adapter...
  • Page 18 NOTE: The following control panel diagrams are for explanatory purposes only. The control panel of the unit you purchased may be slightly different. Your machine may not contain some indicators or buttons. The actual shape shall prevail. NOTE: On some models, is used instead of °F.
  • Page 19 time to turn on Wireless function and the LED some models, selecting AUTO fan speed DISPLAY shows 'ON' for 3 seconds. illuminates all the fan indicator lights NOTE: When you restart the Wireless function, NOTE: In cooling or DRY mode, press the button it may take some time to connect to the for 3 seconds to turn the constant fan function network automatically.
  • Page 20: Other Features

    initiate the Auto-off stop program and illuminate the TIMER OFF indicator light. Press the up or down button to select the desired time. Press the TIMER button again within 5 seconds to initiate the Auto-on start program and illuminate the TIMER ON indicator light.
  • Page 21: Airflow Direction Adjustment

    AIRFLOW DIRECTION ADJUSTMENT that there are no kinks that will stop the water flow. The louver can be adjusted automatically. Adjust the Place the end of the hose into the drain and make sure airflow direction automatically: the end of the hose is down to let the water flow smoothly.(See Figs with .
  • Page 23 The water collection tray is full. Turn off the unit, drain the water from the tray and restart the unit.