PACKAGED TERMINAL
AIR CONDITIONER/HEAT PUMP
Model:
311410571 311410583
311410580 311410575
311410570 311410579
311410585 311410584
Before using your air conditioner, please read
this manual carefully and keep it for future reference.

Advertisement

loading

Summary of Contents for Garrison 311410571

  • Page 1 PACKAGED TERMINAL AIR CONDITIONER/HEAT PUMP Model: 311410571 311410583 311410580 311410575 311410570 311410579 311410585 311410584 Before using your air conditioner, please read this manual carefully and keep it for future reference.
  • Page 2 CONTENTS 1. SAFETY PRECAUTIONS..............2 2. IMPORTANT SAFETY INSTRUCTIONS ..........5 3. AIR CONDITIONER FEATURES............6 4. CONTROL PANEL OPERATION............7 5. DIP SWITCHES CONFIGURATION............8 6. DIP SWITCHES CONFIGURATION BY PANEL CONTROL.....10 7. WALL THERMOSTAT TERMINAL............11 8. INSTALLATION..................13 9. CARE AND CLEANING..............15 10. TROUBLESHOOTING..............16...
  • Page 3: Read This Manual

    Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips.
  • Page 4 Do not operate or s top Do not damage or Plug in power plug the unit by ins erting or use an unspecified properly. pulling out the power power cord. plug. therwise, it may cause t may cause electric shock t may cause electric shock or fire.
  • Page 5 t may cause explosion, fire and burns. Do not clean the air Ventilate the room When the air filter is to well when used be removed, do not touch conditioner with water. together with a the metal parts of the unit. stove, etc.
  • Page 6 Always insert the Do not place obstacles Ensure that the installation filters securely. Clean around air inlets or bracket of the outdoor filter once every two inside of air-outlet. appliance is not damaged weeks. due to prolonged exposure. t may cause failure of f bracket is damaged, there peration without filters may cause failure.
  • Page 7 extension cord or an adapter plug. Do not remove any cord from the manufacturer.
  • Page 8 air conditioner. button. You button. You (this is indicated on some products by a light on the plug head). new one can be obtained from the manufacturer If power supply cord is damaged, it can not be repaired. It MUST be replaced by one from the manufacturer. When 265V units are to be installed,the power supply must be permanent wiring.Permanent wiring may be done through the accessory subbase.
  • Page 9 or heating mode.The temperature can be set in for 3 seconds to alternate the temperature display In cooling mode, press the button to turn the constant fan function on or off. When the function is turned on, the constant fan light will illuminate, identifying the fan is running continuously for cooling.
  • Page 10 (Pads on the control panel are not available.The unit can be set by using wire cotroller only ). ou can install the accessory on the control panel. operation after 3 seconds when any button is pressed. NOTE: When there are wide differences between USERS MANUAL and Remote Control Illustration on function description, the description on USERS MANUAL shall prevail.
  • Page 11 Low temp. protection enable Low temp. protection disable Consult with the sales agency Use some type of wall other wall Use PTAC or manufacturer for details thermostat thermostat Use control panel or some Use control panel or some Use control panel only type of wall thermostat (the type of wall thermostat other one must be turned off)
  • Page 12 Turn off the unit. Press the up ( ) and down ( ) buttons together for 3 seconds to activate the dip switch configurations by panel control (see Fig.4). See Table 1 for dip switch configurations and functions by panel control. NOTE: Press the up ( ) and down ( ) buttons together for 3 seconds again or no operation within 30 seconds to exit the dip switch...
  • Page 13 thermostat consult...
  • Page 14 The controller can handle a switch signal from FC(L) and FC(N) input, called front desk control. Input must be 24VAC. If system doesn't receive a 24VAC signal, it will turn unit off; otherwise, the unit runs in normal control. - The dip switch can control the FRONT DESK CONTROL feature.
  • Page 15 Air conditioner is HEAVY, so use 2 people to lift. airflow...
  • Page 16 required. inward...
  • Page 17 Turn unit off and disconnect power supply.To clean, use water and a mild detergent. use bleach and abrasives. Some commercial cleaners may damage the plastic parts. - Coil on outdoor side of unit should be checked regularly.Unit will need to be removed to inspect dirt buildup that will occur on the inside of the coil.
  • Page 18 Check that plug is securely in wall receptacle. dip switch settings. Check dip switch and wall thermostat settings for desired comfort.
  • Page 19 When outdoor temperature is approximately 55°F or below power has restarted,a random compressor restart will occur. o prevent short cycling of the compressor, there is a random startup delay of 3 minutes and a minimum compressor run time of 3 minutes. Have the evaporator cleaned once every three months by professionals.
  • Page 20 The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.