key is pressed. For instructions on zone bypassing and program-
ming Bypass Groups, see the Power864 Instruction Manual.
[25]-[26] - For future use
[27] - Select Partition 3
[28] - Select Partition 4
[29] - Select Partition 5
[30] - Select Partition 6
[31] - Select Partition 7
[32] - Select Partition 8
These keys provide users with an easy way to select one of the
above partitions. For example, this is the same as pressing and
holding the [#] key, then pressing and holding the [3] key to
select Partition 3 (see section 4.5 "Global and Partition Keypad
Operation" on page 19).
4.5

Global and Partition Keypad Operation

A global keypad will display limited information until a partition
is selected: the Trouble light will turn on if a trouble condition is
present, and the Armed light will turn on if all the partitions are
armed. To select a partition the user must press and hold one of
keys [1] - [8] for two seconds, depending on which partition they
want to access. (e.g. press and hold [2] for Partition 2). The key-
pad will then display the status of the selected partition and
allow normal operation.
A Partition keypad will display the status of the Partition it is
assigned to. A user with access to more than one partition may
temporarily assign the keypad to another partition to gain access.
To do this the user must first press and hold the [#] key for two
seconds. The keypad will go blank. The user must then press and
hold one of keys [1] - [8] for two seconds, depending on which
partition they want to access (e.g. press and hold [2] for Partition
2). The keypad will then display the status of the selected parti-
tion and allow normal access.
K e y p a d C o m m a n d s : 4 . 5 G l o b a l a n d P a r t i t i o n K e y p a d O p e r a t i o n
4.6

Features Available for the LCD5500Z

These features are only available for LCD5500Z keypads with
zone inputs:
Automatic Scrolling of Alarms in Memory
The LCD5500Z keypad allows automatic scrolling through alarms
in memory while the keypad is idle. This feature, if enabled, will
override the clock display. This option can be programmed in LCD
programming section [076], option [4].
24 Hour Time Display Option
The LCD5500Z can be programmed to display time using a 24-
hour clock, instead of a 12-hour, a.m./p.m. clock. This option can
be programmed in LCD programming section [076], option [3].
Keypad Zones
See section 2.10 "Keypad Zones" on page 10.
Viewing Troubles While Armed
See section "[*][2] Trouble Display" on page 15 for information
on how to view troubles.
Backlighting Boost (available for all zone input key-
pads)
The LCD5500Z and PC55XXZ zone input keypads will provide
extra number pad lighting when any key is pressed. The back-
lighting boost will last for an additional 30 seconds after the last
keypress.
Prompts for the following features are only sup-
ported by LCD5500(Z) v2.x and higher:
• Downlook Support (DLM-4L/PC5108L): Active Camera Moni-
tor Selection, Remote Trigger
• Auto Arm features: Late to Close, Auto Arm Postpone/Can-
cel, Auto Arm by day
• Bypass groups
19