Power Parameters; Non Doubler Aht1U Applications - ADC HiGain HLU-200 User Manual

List 1a line unit
Hide thumbs Also See for HiGain HLU-200:
Table of Contents

Advertisement

350-200-111-02, Issue 2
P
OWER
N
D
ON
OUBLER
This section discusses HLU-200 List 1A operations when used without
doublers. Nondoubler HLU-200 current drains on the two CBA power
supplies, power consumption and dissipation are listed in
Table 6. HLU-200 List 1A Power Parameters for Non-doubler Applications
Power Bus
+5 Vdc
-48 Vdc
Power Consumption
Power Dissipation
(1) CPE-I = Customer Premises Equipment current
The maximum power dissipation measures the power converted into heat
inside the unit. It contributes to the total heat generated in the space around
the unit.
The maximum power consumption is the total power that the HLU draws
from the CBA power buses. This parameter is needed when the
Litespan-2000 is battery powered. It determines the battery capacity required
to maintain an 8-hour, standby battery reserve for emergencies.
The HLU line power supply converts the -48 Vdc battery output to -130 Vdc
(-200 Vdc for doublers), which provides a simplex power feed on the two
HDSL line interfaces.
HLU-200 List 1A
P
ARAMETERS
AHT1U A
Line-powered HRU
(1)
CPE-I
OFF
600 mA
133 mA
9.38 W
4.23 W
October 4, 1999
PPLICATIONS
(1)
CPE-I
ON
600 mA
200 mA
12.6 W
4.88 W

Power Parameters

Table
6.
Locally-powered HRU
(1)
CPE-I
ON or OFF
600 mA
0 mA
2.9 W
2.9 W