Remote Controller

A standard remote controller (MC-601) is supplied as a standard together with any outdoor model water heater. The
indoor models are supplied with a non-removable controller on the front panel.
However, it is possible to add up to three additional remote controllers on both product ranges (outdoor and indoor), to
When more remote controllers are connected to the unit, only one of them can be set as the main or the 'Master'.
Normally it is selected, as 'Master' controller, the one located in the kitchen and it is set to a maximum temperature of
55°C. It is always possible to raise this limit but it is not strictly necessary for normal domestic use: this temperature
increase leads to a higher gas consumption and a potential risk from scalding.
The additional controllers connected are recognized as 'Sub' controllers (secondary); they are generally intended for
the use in environments other than the kitchen: bathroom, laundry, etc. The maximum temperature they are allowed to
select is electronically limited to 50°C: this is to reduce the risk of hot water burns as much as possible.
Instructions for the installation of the remote controller are given below.
General Information
It is possible to connect to a water heater to a maximum number of four controllers. It is possible to install Standard
remotes (MC-601) or any combination of Standard, Deluxe 'kitchen' (MC-100V) or Deluxe 'bathroom' (MB-100V)
remotes respectful of the following rules:
Only one 'Master' controller can be installed: a Deluxe 'kitchen' (MC-100V) or a Standard (MC-601).
By connecting a Deluxe 'kitchen' control, this is automatically recognized as 'Master' (this is an
unchangeable factory setting).
NOTE
A maximum of two Deluxe 'bathroom' (BC-100V) controls can be installed.
The fourth remote control must be of the Standard type (MC-601).
To learn more about the Deluxe remote controls, contact Rinnai or visit: www.rinnaiuk.com.
Location
Do not install water controllers near a heat source, such as a cook top, stove or oven. Heat,
steam, smoke and hot oil may cause damage.
NOTE
Do not install water controllers outdoors unless protection from water/dust ingress and
sunlight are provided.
The water controller set as the master water controller must not be installed in a bathroom.
Do not install water controllers in direct sunlight.
Do not install water controllers against a metal wall unless the wall is earthed.
Water controllers must not be installed where chemicals such as benzene, alcohol, turpentine,
hydrogen sulphide, ammonia, chlorine or other similar chemicals are in use.
The Water controller is a water resistant device, however excessive exposure to water may
result in damage to the water controller. Durability is improved when positioned outside the
shower recess.
Avoid direct exposure to water or steam as these conditions may cause a malfunction.
Water controllers must be installed in shaded and clean locations.
Water controllers must be installed at least 40cm above the highest part of a sink, basin or bath.
When cleaning your water controller use only a damp cloth and a mild detergent.