Wireless Communication With Network By Dwa 131 E1 Dongle Unsuccessful; Vci Manager Displays A Yellow Icon On Vdi Iii After Use Of The Device; Computer Application Is Unable To Communicate With Vdi Iii By Usb - Bosch SAIC VDI III Operating Instruction

Diagnostic instrument kit
Table of Contents

Advertisement

6.8
Wireless communication with
network by DWA 131 E1 dong-
le unsuccessful
The D-Link DWA 131 E1 dongle is not intended
to be used for wireless communication of a
computer with a network. The DWA 131 E1
dongle is only intended to be used with VDI III
for point-to-point communication or wireless
communication of infrastructure.
Recommendations
Adjusting the power options:
1. Press <Win>+<X>, and select "Device Mana-
ger" from the list shown.
2. In the list of devices shown, right-click the
"DWA 131" entry.
3. Select "Properties."
4. Select the "Power Management" tab.
5. Deselect the option "Allow the computer to
turn off this device to save power."
Eliminating sources of interference
1. Make sure you do not have two D-Link wire-
less dongles connected to the computer.
2. Make sure the computer does not use the
DWA 131 E1 dongle to connect to the work-
shop network instead of VDI III.
6.9
VCI Manager displays a yellow
icon on VDI III after use of the
device
There may be instances when Windows
does not recognize the installation of the
DWA 131 E1 wireless adapter. In these cases,
Windows may create a new wireless profile
instead of using the existing one already stored
on the computer. The yellow icon displayed
on VDI III means that the USB connecting cab-
le between VDI III and the computer must be
plugged in.
Recommendations
Unplug and then re-install the wireless adap-
ter. Windows will attempt to recognize the
wireless adapter. If the attempt is success-
ful, the yellow icon will disappear and VDI III
will be ready for a wireless point-to-point
connection.
Robert Bosch GmbH
Troubleshooting | VDI III | 19
6.10
Computer application is unable
to communicate with VDI III by
USB
VCI Manager must be installed on the computer
and VDI III must be switched on for the connec-
tion to work. VDI III must be configured by USB
before it can communicate using any other
connection type.
Recommendations
If other applications, including VCI Manager,
are able to connect to VDI III, proceed as fol-
lows:
Check the Windows Firewall settings to see
if the application is being blocked.
If all installed applications are unable to com-
municate with VDI III, proceed as follows:
1. Use the USB connecting cable to connect
VDI III to the computer, not to the vehicle.
!
Do not connect the USB connecting cable of
VDI III to a USB hub.
2. Verify that the USB connecting cables are
securely attached and VDI III has fully boo-
ted up.
3. Start the "VCI Manager" program.
4. Does VCI Manager detect VDI III?
If not:
$
Try a different USB connecting cable / port
on the computer.
$
Check the Windows Firewall to see if VCI
Manager is being blocked.
$
Check if the VDI III USB connection is
detected by Windows.
2020-01-01
en
|
1 689 989 458