20 | VDI III | Cleaning and maintenance
6.11
Computer application is unable
to communicate with VDI III by
WLAN or Ethernet
1. Make sure the WLAN USB adapter is securely
attached to VDI III.
2. Make sure VDI III can make a connection by
USB.
3. If using point-to-point, make sure the compu-
ter has no more than one dongle connected
to it:
$
Connect VDI III to the computer by USB.
$
In VCI Manager, make sure the connection
is enabled and the IP configuration is
correct.
4. If using the workshop's WLAN network:
Contact the IT department and make sure the
computer is detecting the access point and the
security settings for VDI III have been configu-
red correctly.
7.
Cleaning and mainte-
nance
The housing of VDI III may only be cleaned with a
soft cloth and a neutral cleaning agent. Do not use
abrasive cleaning agents or coarse workshop rags.
i
VDI III does not contain any parts that can be
maintained by the user. Do not open VDI III.
Opening it will void the warranty.
Do not immerse VDI III or any of its parts or
accessories in water.
Even though VDI III and its accessories are
water-resistant, they are not waterproof. Allow to
dry completely before storing.
Avoid using harsh solvents such as petrole-
um-based cleaning agents, acetone, benzene,
trichloroethylene etc.
|
1 689 989 458
2020-01-01
7.1
Restoring the VDI III system soft-
ware (recovery)
As a result of a power failure or a connection error
during a software update, the VDI III software may
become corrupted. In this case, it is necessary to
perform a recovery:
1. Connect VDI III to the computer by USB connec-
ting cable.
2. Launch VCI Manager.
3. Select VDI III in "VCI Explorer."
4. To start the recovery, press and hold the power
button on VDI III for at least 5 seconds.
 The VDI III icon in VCI Manager is marked "Re-
covery."
5. Select VDI III in VCI Manager.
6. Carry out recovery.
7.2

Spare and wearing parts

Kit component
VCI system tester
Diagnostic connection cable
(data transmission to J1962)
USB connecting cable A to B, 3 m
WLAN USB stick
1)
Test adapter (self-test)
1) 2)
1) Wearing part
2) Special accessory
Part number
1 699 200 873
1 699 200 366
1)
F00K.108.653
1)
1 687 010 590
1 699 200 154