FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (inches w.g.)
MODEL
4 -
3 -
CDX1B040A9241A
2 -
1 -
4 -
3 -
CDX1B060A9361A
2 -
1 -
4 -
3 -
CDX1B080A9421A
2 -
1 -
4 -
3 -
CDX1C100A9481A
2 -
1 -
4 -
3 -
CDX1D120A9601A
2 -
1 -
MODEL
600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400
CDX1B040A9241A
56
CDX1B060A9361A
CDX1B080A9421A
CDX1C100A9481A
CDX1D120A9601A
WARNING
!
EXPLOSION HAZARD!
NEVER USE AN OPEN FLAME TO DETECT GAS LEAKS.
EXPLOSIVE CONDITIONS MAY OCCUR. USE A LEAK TEST
SOLUTION OR OTHER APPROVED METHODS FOR LEAK
TESTING. FAILURE TO FOLLOW THIS WARNING COULD
RESULT IN PROPERTY DAMAGE, PERSONAL INJURY OR
DEATH.
WARNING
!
SAFETY HAZARD
DO NOT USE THIS UNIT IF ANY PART HAS BEEN UNDER
WATER. A FLOOD DAMAGED UNIT IS EXTREMELY DANGER-
OUS. ATTEMPTS TO USE THE FURNACE CAN RESULT IN
FIRE OR EXPLOSION. A QUALIFIED SERVICE AGENCY
SHOULD BE CONTACTED TO INSPECT THE FURNACE AND
TO REPLACE ALL GAS CONTROLS, CONTROL SYSTEM
PARTS, ELECTRICAL PARTS THAT HAVE BEEN WET OR THE
FURNACE IF DEEMED NECESSARY.
FAILURE TO FOLLOW THIS WARNING COULD RESULT IN
PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Page 44
SPEED TAP
0.10
HIGH - Black
998
MED.-HIGH - Blue
856
MED.-LOW - Yellow
753
LOW - Red
647
HIGH - Black
1341
MED.-HIGH - Blue
1198
MED.-LOW - Yellow
1369
LOW - Red
784
HIGH - Black
1547
MED.-HIGH - Blue
1487
MED.-LOW - Yellow
1388
LOW - Red
1263
HIGH - Black
1892
MED.-HIGH - Blue
1779
MED.-LOW - Yellow
1630
LOW - Red
1444
HIGH - Black
2213
MED.-HIGH - Blue
2057
MED.-LOW - Yellow
1765
LOW - Red
1468
CFM VS. TEMPERATURE RISE
48
42
37
34
63
56
51
46
68
61
0.20
0.30
0.40
965
922
870
832
797
751
728
694
650
617
581
538
1285
1223
1156
1161
1115
1060
1232
1108
998
781
767
741
1498
1445
1386
1436
1382
1325
1348
1302
1249
1234
1196
1150
1827
1762
1688
1726
1672
1605
1587
1544
1485
1416
1388
1348
2138
2062
2001
2000
1943
1883
1733
1700
1652
1452
1435
1409
Cubic Feet Per Minute (CFM)
42
39
36
34
56
52
48
45
42
65
60
56
53
67
63
EXPLOSION HAZARD
SHOULD OVERHEATING OCCUR, OR THE GAS SUPPLY FAIL
TO SHUT OFF, SHUT OFF THE MANUAL GAS VALVE TO THE
FURNACE BEFORE SHUTTING OFF THE ELECTRICAL
SUPPLY.
FAILURE TO FOLLOW THIS WARNING COULD RESULT IN
PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
EXPLOSION HAZARD
TO PREVENT AN EXPLOSION OR POSSIBLE INJURY, DEATH
AND EQUIPMENT DAMAGE, DO NOT STORE COMBUSTIBLE
MATERIALS, GASOLINE OR OTHER FLAMMABLE VAPORS OR
LIQUIDS NEAR THE UNIT.
FAILURE TO FOLLOW THIS WARNING COULD RESULT IN
PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
0.50
0.60
0.70
807
735
653
695
628
550
596
533
460
490
435
375
1082
1004
919
996
923
842
901
817
747
703
654
593
1323
1254
1180
1265
1202
1137
1191
1126
1056
1095
1032
960
1614
1531
1448
1538
1460
1381
1426
1362
1297
1308
1246
1184
1939
1863
1786
1822
1752
1681
1603
1552
1500
1382
1336
1290
40
50
47
44
42
40
59
56
53
51
48
WARNING
!
WARNING
!
Pub. No. 41-5016-12
0.80
0.90
561
459
462
363
378
286
308
235
829
734
751
652
689
645
521
437
1101
1016
1069
998
979
896
879
790
1354
1260
1291
1200
1208
1119
1108
1032
1706
1625
1595
1508
1424
1347
1225
1159
38
37
35
46
44
42

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents