Chapter 13. Test Data At A Glance - Sharp R-239 Service Manual

Table of Contents

Advertisement

R239(W)
CHAPTER 13.
R239(W)
TEST DATA AT A GLANCE
PARTS
Fuse
High voltage fuse
Temperature fuse
Oven lamp
High voltage capacitor
Magnetron
High voltage transformer
WARNING: DISCONNECT THE PLUG WHEN MEASURING RESISTANCE
SYMBOL
F1
T6.3A 250V
F2
0.6A 5kV
TF
150°C
OL
240V 25W
C
0.91μF AC 2100V
Filament < 1Ω / Filament - chassis ∞ ohm
MG
T
Filament winding < 1Ω
Secondary winding Approx. 208Ω
Primary winding Approx. 2.7Ω