10 CHECKS AND ADJUSTMENTS
Target Plate
approx. 50 m
10mm
10mm
Internal circle
+
+
20mm
20mm
Laser spot "Center"
[Example: Adjustment is necessary]
[Example: Adjustment is unnecessary]
Adjustments
At the procedure 4. above, if the "Center" of laser spot is not within the internal
circle (10mm) of the target plate, the adjustment is necessary. Please contact
your PENTAX dealer.