TROUBLESHOOTING
The door remains
The sensor power is off.
closed.
The LED is OFF.
The door does not
Improper output
react as expected.
configuration on the sensor.
The door opens
The sensor is disturbed
and closes
by the door motion or
constantly.
vibrations caused by the
door motion.
The door opens for
It rains and the sensor
no apparent reason.
detects the motion of the
rain drops.
In highly reflective
environments, the sensor
detects objects outside of its
detection field.
In airlock vestibules,
the sensor detects the
movement of
the opposite door.
Detection area is too
Sensitivity is too low
small
Height mode is error set
BEA |4th Floor, 401room, M8 Building / No. 1 Jiuxianqiao East Road, Chaoyang District, Beijing,PRC | T +86 10 57761616 / F +86 1062628775 www.bea-asiapacific.com
Check the wiring and the power supply.
1
1
Change the output configuration setting on
each sensor connected to the door operator.
1
Make sure the sensor is fixed properly.
2
Increase the antenna angle.
3
Increase the immunity filter.
4
Reduce the field size.
1
Increase the immunity filter.
2
Install the ORA (rain accessory).
1
Change the antenna angle.
2
Decrease the field size.
3
Increase the immunity filter.
Change the antenna angle.
2
Increase the immunity filter.
Adjust sensitivity potentiometer, increase
sensitivity.
When mounting height is more than 3 meters,
2
turn the switch 3 to ON.
Please keep for further use
Designed for colour printing
Other use of the device is outside the permitted purpose and can not be
guaranteed by the manufacturer.
The manufacturer cannot be held responsible for incorrect installations or
inappropriate adjustments of the sensor.
DESCRIPTION
2
1
radar antenna
1.
2.
main connector
3.
LED
4.
DIP-switch
5.
sensitivity adjustment
6.
immunity adjustment
7.
cover
TECHNICAL SPECIFICATIONS
Technology:
microwave doppler radar
Transmitter frequency:
24.150 GHz
Transmitter radiated power:
< 20 dBm EIRP
Transmitter power density:
< 5 mW/cm²
Detection mode:
motion
Min. detection speed:
5 cm/s (measured in sensor axis)
Supply voltage:
12 V to 24 V AC ±10%; 12 V to 24 V DC +30% / -10%
Mains frequency:
50 to 60 Hz
Max power consumption:
< 2 W
Output:
relay (free of potential change-over contact)
Max. contact voltage:
42 V AC/DC
Max. contact current:
1 A (resistive)
Max. switching power:
30 W (DC) / 60 VA (AC)
Mounting height:
from 1.8 m to 4 m
Degree of protection:
IP54
Temperature range:
from -20 °C to + 55 °C
Dimensions:
120 mm (L) x 80 mm (H) x 50 mm (W)
Tilt angles:
0° to 90° vertical; -30° to +30° lateral
Material:
ABS
Cable lenght:
2.5 m
Norm conformity:
R&TTE 1999/5/EC; EMC 2004/108/EC
Specifications are subject to changes without prior notice.
Measured in specific conditions
EAGLE 6+DRO
Opening sensors for automatic doors
EAGLE 6+DRO: bidirectional sensor
3
4
5
6
7

Advertisement

loading

Summary of Contents for BEA EAGLE 6+DRO

  • Page 1 R&TTE 1999/5/EC; EMC 2004/108/EC Specifications are subject to changes without prior notice. BEA |4th Floor, 401room, M8 Building / No. 1 Jiuxianqiao East Road, Chaoyang District, Beijing,PRC | T +86 10 57761616 / F +86 1062628775 www.bea-asiapacific.com Measured in specific conditions...
  • Page 2 ADJUSTMENTS OPENING THE SENSOR DIP 4 DIP 1 DIP 2 DIP 3 NOT USED DETECTION MODE OUTPUT CONFIG. MOUNTING HEIGHT EAGLE 6+DRO bidirectional passive - NC NOT USED 3m-4m bidirectional active - NO 1.8m-3m NOT USED Before fixing After fixing...