Maintenance

Precautions:
Please disconnect power supply before maintenance or repair to
prevent electric shock.
If the dehumidifier is not used for a long time, please disconnect
power supply.
Please do not clean the dehumidifier body with chemical solvents
such as alcohol, gasoline and benzene, etc.
Please clean the water tank and its
cover with soft cloth dipped in cold
or warm water regularly to prevent
mould inside the dehumidifier.
Wipe the surface of the
dehumidifier slightly with wet
cloth, and do not use detergent
or abrasive in case the plastic
surface is damaged.
Description
Displayed code
FL
The water tank is full
E1
The coil sensor detects anomaly
The room temperature sensor
E2
detects anomaly
P1
The unit is in the defrosting state,normal
The unit is in the internal drying state,normal
CL
LC
Child lock is on