1.3 preparation

WARNING! If you need to remove an old door prior to installing a B&D door ensure to:
Roll the door up and place a secure tie around the middle
Place door support on flat ground
Fit door support snugly under door before loosening the brackets or locating U bolts.
Slowly undo bolts to release the spring tension and the door from the brackets.
Slowly lift the door from the brackets keeping it balanced as it is lowered to the ground.

1.4 before installation

1.4.1 requirements

mounting -
The door is designed to be mounted behind the opening.
obstructions
- Ensure that the surface where the door will be fitted
is flush and smooth, and the area behind the opening is free from any
protrusions.
structural suitability -
support the door. If unsure, consult a builder.
level and plumb
level position, if opening is not level and square, appearance and/
or sideroom requirements will be affected. The floor should be level or
recessed across the opening to avoid gaps.

1.4.2 measurements

opening width
- As the standard door overlaps each side by 50mm
or more, the door should be 100mm wider than the opening. A wider
door can be fitted as long as additional sideroom and fixing is available.
(Fig 1.4.1a) Wind-Locked doors require additional overlap dependent on
the substrate, consult the B&D High Wind Certification Drawings for more
detail.
opening height
- The door opening height (or drive through
clearance) indicates the distance between the ground and rubber
seal at the bottom of the door, with door fully open. Max drive through
heights for each door height are listed in Fig 1.4.1b.
headroom
- A minimum headroom is required for all doors. Refer to
Fig 1.4.2 - 1.4.5 for measurements. If the door is installed lower into the
opening than shown in Fig 1.4.2, additional loss of door opening height
will result.
backroom
- A minimum of
R2L doors up to 2400mm. For other doors, refer to Fig 1.4.2 - 1.4.5 for
measurements.
Fig: 1.4.1b
Name
Description
Type
Model code
Door & Max Drive Through
Heights (mm)
(non-Wind-Lock Doors)
Max Door Width (including
overlap)
Ensure the opening is strong enough to
- The door must be installed in an absolutely
460mm of backroom is required for
Low Profile
Series 2
R2L
Max Drive
Door Height
Door Height
Height
-
-
-
-
2400
2300
3000 (WA)
3000
3300 (WA)
3300
-
-
-
-
-
-
5500mm
Traditional
Series 2
R2W
Max Drive
Door Height
Height
1400
1350
2100
2000
2100
2400
2300
2400
3000
2985
3000
-
-
3300
-
-
3600
-
-
4200
-
-
5100
5500mm
DO NOT CUT THE
PACKAGING THAT HOLDS
THE DOOR IN A ROLL
At a later stage during
the installation you will
be told just when to cut
the packaging. Remove
brackets, guides and bag
of small parts from each
end of the door roll.
BACKROOM
OPENING
WIDTH
LINTEL HEIGHT
Fig: 1.4.1a
Industrial
Light Industrial
Series 2
R2I
Max Drive
Door Height
Height
-
-
-
2000
2100
2300
2400
3000
3000
3300
3300
3600
3600
4200
4200
5100
5100
5500mm
5
Series 2
R2F
Max Drive
Height
-
2000
2300
3000
3300
3600
4200
5100
5100mm