Install Guides - B&D Roll-A-Door 2 Series Installation Instructions Manual

Hide thumbs Also See for Roll-A-Door 2 Series:
Table of Contents

Advertisement

Roll-A-Door
Series 2 installation instructions
®

2.4 install guides

2.4.1 positioning guides
WARNING! Do not grease the guides. Grease will
damage the Nylofelt
heavier to operate.
CAUTION: Restricted headroom installation is not
recommended for automated doors unless the door is
installed lower into the opening. NOTE: This will reduce
the drive through height.
guide clip
WARNING! All High Wind installations must adhere to fixing types and centres as referenced in the
Drawings
and
B&D High Wind
If securing to uneven brickwork, packers may be required behind clips, to prevent them twisting out
tip
of square; also ensure that clips are positioned on secure bricks.
a) Check that curtain overlaps equally on both sides.
b) Check that guides
C
the brackets (or as per table above at position G). (Fig 2.4.1) If guides
need to be shortened cut from bottom of guide.
c) For Series 2 Doors:
(i) Now position one guide over the edge of the door
curtain. Mark and drill the top fixed guide clip and
secure using correct fixing and washers as per table
in Section 1.2, allowing 3-4mm clearance between
the door and the inside of the guide.
(ii) Ensuring guide is plumb, using spirit level, then drill and
fix remaining clips and head stop.
For Series 2 Windlock Doors:
(i) If there is limited sideroom available the guide may
need to have the side cut out to accommodate. See
Fig 2.4.2 for recommended and restricted sideroom
with a clearance of 2-5mm to the bottom rail roller.
(ii) Now position one guide over the edge of the door
curtain. Mark and drill at top guide hole and secure
guide using fixing types as per
Drawings, taking note of the specific spacing
requirements.
(iii) Ensuring guide is plumb, drill and fix remaining holes in
guide as per spacing details listed.
d) With the top of the 2nd guide level with the first, repeat (c)
for the specific door type.
NOTE: Welding of guides to steelwork is usually not
recommended
®
running strips and make doors
G
bracket arm
cushion head stop
Fig: 2.4.1
Drawings.
are the correct length, that is, starts level with
High Wind Certification
dimension panel
height (mm)
width (mm)
up to 2400
up to 5500
2401-3300
up to 5500
3301-4200
up to 5500
4201-5100
up to 5500
up to 2400
up to 5500
2401-3300
up to 5500
3301-4200
up to 5500
4201-5100
up to 5500
up to 2400
up to 5500
2401-3300
up to 5500
up to 2400
up to 5500
2401-3300
up to 5500
R2F has a maximum width of 5100mm.
*R2L Only, above 2400mm only available in WA
B
B
C
Recommended
Sideroom
Fig: 2.4.2
10
G
0
0
0
0
60
60
60
40
90*
60*
0
0
DTCM
C
Restricted
Sideroom

Advertisement

Table of Contents
loading

Table of Contents