5
Mode transition and structure of layers in Service Factory mode
Mode transition in Service Factory mode
Up
• To shift to another mode, press [MUTING].
• To shift to another item in a specific mode,
press [i] or [j].
• To shift to the next nested layer below for an
item with a "(+)" indication, press [ENTER/SET].
To return to the next nested layer above,
also press [ENTER/SET].
Down
INFORMATION mode
1. VERSION (1)
2. VERSION (2)
3. MAIN NG
4. TEMPERATURE
5. HOUR METER
6. HDMI SIGNAL INFO1
7. HDMI SIGNAL INFO2
8. VDEC SIGNAL INFO1
9. VDEC SIGNAL INFO2
PANEL FACTORY mode
1. PANEL INFORMATION
2. PANEL WORKS
3. POWER DOWN
4. SHUT DOWN
5. PANEL-1 ADJ
6. PANEL-2 ADJ
7. PANEL FUNCTION
8. ETC.
9. RASTER MASK SETUP
10. PATTEN MASK SETUP
11. COMBI MASK SETUP
Structure of Layers in Panel Factory Mode 1
1. PANEL INFORMATION
Version indication of the panel
2. PANEL WORKS
Indications of the accumulated power-on time, pulse-meter
count, and power-on count of the panel
3. POWER DOWN
Indication of the Power-down history
4. SHUT DOWN
Indication of the Shutdown history
5. PANEL-1 ADJ (+)
1. VOL SUS
2. VOL OFFSET
Settings required after replacement of the panel
• • • • •
8. VOL YNOFS4
9. RESET1ST_KSB
Modification not required because these items
10. RESET2ND_KSB
are basically for factory presetting
• • • • •
23. YSTL_FMR_HZ
24. SUS FREQ
For AM noise prevention (Depending on the mode,
brightness of the screen changes.)
For confirmation of the result of the setting change,
the unit must be turned off then back on again.
6. PANEL-2 ADJ (+)
1. R-HIGH
2. G-HIGH
3 .B-HIGH
Parameters for the WB adjustment of the panel, which are
4. R-LOW
required during adjustment after panel replacement
5. G-LOW
6. B-LOW
7. ABL
Setting of the power consumption. A setting table is
available for each vertical signal.
To "Structure of Layers in Panel Factory Mode 2"
5
6
Quick Reference upon Service Visit 2
Structure of Layers in Service Factory Mode
INFORMATION mode
1. VERSION (1)
2. VERSION (2)
3. MAIN NG
4. TEMPERATURE
5. HOUR METER
6. HDMI SIGNAL INFO 1
INITIALIZE mode
7. HDMI SIGNAL INFO 2
1. SIDE MASK LEVEL
8. VDEC SIGNAL INFO 1
2. FINAL SETUP
9. VDEC SIGNAL INFO 2
3. Wide XGA AUTO
PANEL FACTORY mode
OPTION mode
1. EDID WRITE MODE
2. CH PRESET
3. AFT
4. SYNC DET
INITIALIZE mode
1. SIDE MASK LEVEL
OPTION mode
1. EDID WRITE MODE
2. FINAL SETUP
2. CH PRESET
3. AFT
3. Wide XGA AUTO
4. SYNC DET
Structure of Layers in Panel Factory Mode 2
7. PANEL FUNCTION (+)
8. ETC (+)
9. RASTER MASK SETUP (+)
10. PATTEN MASK SETUP (+)
11. COMBI MASK SETUP (+)
PDP-508XG
6
7
The software versions for each microcomputer
The Flash memory versions for each device
The shutdown message ID/event times
(Going Clear mode by [ENTER/SET] key)
Select Yes by [l] key, l pressing and hold [ENTER/SET] key
3-1. CLEAR
The temperature/FAN rotating status/Room light sensor
The HOUR METER/P-COUNT information
The information of HDMI information files
The information of HDMI information files
The signal information of VDEC
The signal information of VDEC
Refer to [PANEL FACTORY MODE]
For factory use
For production line use
For factory use
For technical analysis
For factory use
1-1. SIDE MASK LEVEL
Set to Factory default settings (it should perform after
2-1. DATA RESET
replacing a MAIN Assy)
For technical analysis
1. R-LEVEL
2. G-LEVEL
3. B-LEVEL
4. ADDRESS L1
Items for use by engineers
5. ADDRESS L2
• • • • •
11. ADDRESS U4
12. STK MODE
1. BACKUP DATA
For transferring backup data (after replacement of
the DIGITAL Assy)
2. DIGITAL EEPROM
To clear data of the digital video
3. PD INFO.
4. SD INFO.
For clearance of data for the corresponding items.
5. HR-MTR INFO.
The clearing method is the same: Select "CLEAR",
6. PM/B1-B5
using [l], then hold [ENTER/SET] pressed for at
7. P COUNT INFO.
least 5 seconds. After clearance is completed, {ETC}
8. MAX TEMP.
is automatically selected.
1. MASK OFF
2. RST MASK 01
For use while Raster Mask (full mask) is displayed.
• • • • •
Use [i] or [j] to select the type of mask.
26. RST MASK 25
1. MASK OFF
2. PTN MASK 01
For use while Pattern Mask is displayed. Use [i] or
• • • • •
[j] to select the type of mask.
50. PTN MASK 49
1. MASK OFF
2. CMB MASK 01
For use while Combination Mask is displayed.
• • • • •
Use [i] or [j] to select the type of mask.
18. CMB MASK 17
7
8
A
B
C
D
E
F
9
8