Leds - IBM SAN48C-6 Installation, Service And User Manual

Table of Contents

Advertisement

• Red—Port-side intake airflow
• Blue—Port-side exhaust airflow
The switch supports PSUs of only one airflow type at a time. Both PSUs have to be either port-side
exhaust, or port-side intake PSUs.
Note: The direction of PSU airflow must match the direction of the fan module airflow.
For more information on installing and removing PSUs, see Installing and Removing Power Supplies.

LEDs

The IBM SAN48C-6 switch has LEDs on both the front and back of the switch to indicate the status of
different system components during boot-up tests and online operation. The following tables describe the
location of each LED and the meaning of its color:
Table 2. Chassis Activity LEDs for a IBM SAN48C-6 Switch
Indicator
Location
Power LED
Front panel of
the chassis
Function
Color
Chassis Power/
Off
Health
Green
Red
Chapter 1. Overview of the IBM SAN48C-6 Fibre Channel Switch 5
Status
State
Off
Either of the following
conditions exists:
• The system is not
receiving sufficient power
from the PSUs.
• The operating system is
not running.
Solid On
Both PSUs are installed and
operational.
Solid On
Either of the following
conditions exists:
• A PSU has failed.
• A PSU has been removed.

Advertisement