B. LEFT AND RIGHT DIRECTION
• The left and right airflow direction can be fixed at
the desired position manually.
NOTE
• Only make adjustments after you have fixed the
up and down airflow direction in a position. Your
hand may get caught if you attempt to make
adjustments while the horizontal blade is
swinging.
• Stop the horizontal blade from swinging before
trying to angle them. Working while the blade is
moving may get your fingers pinched.
• The four fins for the left and right airflow direction
operate in the same direction as a unit.
Do not operate adjacent units in the state
shown in the drawing. This may cause dripping
of condensation.
Vertical blade unit (top view)
Air

7. OPTIMUM OPERATION

Observe the following precautions to ensure the air
conditioner operates.
• Prevent direct sunlight from the window by using
curtains or blinds during the COOLING
OPERATION.
• Keep doors and windows closed. If the doors and
windows remain open, room air will flow out and
decrease the effect of cooling and heating.
• Never place objects near the air inlet and the air
outlet of the air conditioner. It may decrease the
effect or stop the operation.
• Adjust the room temperature properly for a
comfortable environment. Avoid excessive
heating or cooling.
Not doing so wastes electricity.
• When the display shows "
filter", ask a qualified service person to clean the
filters.
(Refer to "8. MAINTENANCE" on page 9.)
Operating the indoor unit with stained air filter
may decrease capacity or cause malfunction.
• Install TVs, radios, and stereos 1 m or more away
from the indoor unit and remote controller.
Images may become fuzzy and noise may be
generated.
9
Air
Vertical blades
" or "Time to clean
• Turn off the power circuit breaker when it is not
in use for a long period. When the power circuit
breaker is turned on, small amount of power is
consumed even if the air conditioner is not in
operation. (*1)
Turn off the power circuit breaker for saving
energy. When reoperating, turn on the power
circuit breaker 6 hours before operation for
smooth running.
(Refer to "8. MAINTENANCE" on page 9.) (*2)
*1 The consumed power while the outdoor unit is
not in operation depends on the model.
*2 The setting before the power circuit breaker is
cut off is stored. (The timer setting is cleared.)
• Fully use the function of airflow direction adjust.
Cold air gathers on the floor, and warm air
gathers under the ceiling.
Set the air direction to horizontal during the
COOLING or PROGRAM DRY OPERATION, and
set it downwards during the HEATING
OPERATION.
Do not let the air blow directly to a person.
• Use the TIMER OPERATION effectively.
It takes some time until the indoor temperature
reaches the set temperature. It is advisable to
start operation in advance using the TIMER
OPERATION.
8. MAINTENANCE
(FOR SERVICE PERSONNEL)
ONLY A QUALIFIED SERVICE PERSON IS
ALLOWED TO PERFORM MAINTENANCE
WARNING
• Do not use flammable gas (such as hair
sprays and insecticides) near the air
conditioner.
• Do not wipe the air conditioner with benzine or
thinner.
It may cause cracks, electric shocks or a fire.
• Never put your fingers or rods in the air inlet,
air outlet or air blade.
The fan is rotating at high speed, so you would
get injured.