Sony SNC-CH135 Release Notes page 14

Hide thumbs Also See for SNC-CH135:
Table of Contents

Advertisement

(Problem from Ver.1.05)
19.2. Correction of MPEG-4 SDP data
The extraneous last four bytes of SDP (Session Description Protocol) data for MPEG-4 in
RTSP streaming are removed.
(Problem from Ver.1.05)
19.3. Connectivity with other vendors' client software
There was a problem that connections with Omnicast client software provided by Genetec
may be lost. This problem has been fixed.
(Problem from Ver.1.31)
19.4.
Solid PTZ on ONVIF connection
Absolute Pan/Tilt/Zoom and Relative Pan/Tilt/Zoom functions on ONVIF connection are
supported.
(Problem from Ver. 1.05)
[Note]
Relative Pan/Tilt and Relative Zoom do not work concurrently.
Continuous Pan/Tilt/Zoom functions are not supported.
19.5. Video output signal format problem (SNC-CH180/CH280)
There was the problem that the video output signal format turned out to be NTSC when it
was set to PAL according to the setting of the camera's NTSC/PAL switch and the setting
data of the camera were saved and restored. This problem has been fixed.
(Problem from Ver. 1.05)
19.6. Image 2 setting data restoration problem
There was the problem that the Image 2 setting data may not be restored properly. This
problem has been fixed.
(Problem from Ver. 1.05)
20. Newly Added Functions in Ver. 1.75
20.1. Motion detection / Camera tampering detection / Audio detection support
(SNC-CH135)
SNC-CH135 has not ever supported Motion detection, Camera tampering detection, and
audio detection. From this version these functions are available.
20.2. CGI command setting for WS-Discovery
The following CGI command disables WS-Discovery protocol for ONVIF connection. At this
time the multicast join message packet to 239.255.255.250 is not sent at startup.
http://ip_adr/command/system.cgi?WsDiscovery=off
For details, refer to the CGI Command Manual.
Sony Corporation
Release Note
14

Advertisement

Table of Contents
loading

Table of Contents