Download Print this page

Delete Switching Program; Setting Manual Or Permanent Switching - Theben eltimo 020 top3 Manual

Digital plug-in time switch

Advertisement

Change individual switching times
Press MENU.
Select PROGRAM and press OK to confirm.
Select MODIFY, confirm by pressing OK.
Select day, confirm with OK.
MODIFY HOUR, use the + or – buttons to change hour and
minute and confirm with OK.
To change several switching times, select MODIFY BLOCK,
confirm with OK.

Delete switching program

MENU
PROGRAM
NEW
CHECK
MODIFY
DELETE
u
MONDAY
DELETE
BLOCK
L You can either delete a block, i.e. a switching time copied
for several days (e.g. Mon-Fri) or a single switching time
Press MENU.
Select PROGRAM and confirm with OK
Select DELETE, confirm with OK.
INDIVIDUAL is displayed (with u DELETE ALL),
confirm with OK.
MONDAY is displayed, confirm with OK.
Select DELETE BLOCK, confirm with OK.
With u DELETE MONDAY etc. individual days can also be
cleared.
Setting holiday function
MENU
MANUAL
PERM ON
PERM OFF
OVERR ON
HOLIDAY
u
RANDOM
HOLIDAY
END
END HOLIDAY
Press MENU.
Select MANUAL and press OK to confirm.
Select HOLIDAY and press OK to confirm.
Select ON and press OK to confirm.
Select START HOLIDAY and press OK to confirm.
SINGLE
DELETE
u
ALL
DELETE
SINGLE DAY
ON
BEGIN
Enter YEAR, MONTH, DAY, HOUR and press OK to confirm.
Select END HOLIDAY and press OK to confirm.
Enter YEAR, MONTH, DAY, HOUR and press OK to confirm.
Setting the random function
L The consumer is switched on or off at random. If you con-
nect a lamp, you can simulate presence when you are on
holiday and make it more difficult for burglars.
MENU
MANUAL
PERM ON
PERM OFF
OVERR ON
HOLIDAY
u
RANDOM
RANDOM 1
END
Press MENU.
Select MANUAL, confirm with OK.
Select RANDOM, confirm with OK.
Select RANDOM 1 or RANDOM 2, confirm with OK.
L Random 1: The channel is switched on and off randomly
during the programmed ON switching times, and remains
completely off during the OFF switching times.
L Random 2: The channel is switched on only 1x and swit-
ched off again 1x during the programmed ON switching
times. However, these ON and OFF switches do not occur
exactly at the programmed times, but are offset by a ran-
dom time.

Setting manual or permanent switching

Manual or permanent switching can be set via the menu in
MANUAL or (in the automatic screen) by button combination
(see picture).
Manual control:
Reversing the channel status to the next automatic or
programmed switching.
Permanent switching:
As long as a permanent switching (on or off) is activated,
the programmed switching times are ineffective
Activating manual control
Briefly press both buttons simultaneously.
Activating permanent switching
Press both buttons simultaneously for 2 seconds.
Cancelling manual/permanent switching
Press both buttons simultaneously.
RANDOM 2
ok
3

Advertisement

loading

This manual is also suitable for:

0200130