Page 1
INSTALLATION AND OPERATION MANUAL FREE-STANDING AND INSERT PELLET-FIRED STOVES Free-Standing Model Free-Standing Model Profi le ® 20 FS-2 Profi le 30 FS-2 Insert Model Profi le 30 INS-2 Whitfi eld Profi le Series Pellet Stoves Models Profi le 20 FS and Profi le 30 FS WARNINGS •...
Keep children, clothing and furniture 5. The minimum clearances must IMPORTANT SAFETY AND away. Contact may cause skin burns. be maintained for all combustible WARNIING INFORMATION surfaces and materials including; Do not let children touch the appliance. furniture, carpet, drapes, clothing, Train them to stay a safe distance from wood, papers, etc.
Warnock Hersey. It is our goal at Lennox Hearth Products to provide you, our valued customer, with an appliance Testing: In accordance with the specifi cations that will ensure you years of trouble free warmth and pleasure.
2. Local amendments PLANNING YOUR INSTALLATION WARNING 3. Is a permit required - cost You may wish to contact your insurance Check all local building and Questions To Ask Local Building Offi cial company to ask if they require this. safety codes before installation.
Page 5
® Floor Protection - Profi le 30 FS-2 Minimum k-value (per Inch) of Specifi ed min. thickness of alternate material (k thickness alternate k-value (per inch) of listed The fl oor protector must meet or exceed the minimum thermal require- material (T of listed material (k material (T...
CLEARANCES - FREE-STANDING MODELS Combustible ® Models: Profi le 20 FS-2 and Profi le 30 FS-2 Standard residential or manufactured home installation. These appliances require the following minimum clearances to combustibles: Horizontal Flue – Interior Vertical Profi le 20 FS-2 Directly Through Wall Flue A - Sidewall to unit...
CLEARANCES AND HEARTH PROTECTION - INSERT 24-5/8” Clean-Out Model Profi le ® 30 INS-2 17-3/4” In the USA and Canada, the area below and directly in front of the Profi le Profi le 30-2 INS 30 INS-2 fi replace insert must be an approved fi replace hearth or protected by a non-combustible hearth / fl...
7 feet or less above the ground level The fi replace in which the Profi le on which the manufactured home is position authorized Lennox Hearth Products dealer 30 INS-2 is to be installed must be a guard or method of enclosing the pipe shall install your stove.
Page 9
® Installing Surround Assembly - Profi le 30 INS-2 Damper is factory set to a (to be done after venting system is installed) This fi replace insert gap as specifi ed below. requires surround panels (a set of metal panels that enclose the fi replace opening when fi...
Remove jumper if Thermostat IS to be used package. It is recommended that the thermostat and thermostat wire be installed by an autho- Thermostat wires rized Lennox Hearth Products dealer. and purple wires Terminal from wire harness Block...
Page 11
Size of Pipe Connection to Masonry Chimney through a B. Not less than 4 feet (1.2 meters) below, 4 Wall (Free-Standing Models) feet (1.2 meters) horizontally from or 1 foot These pellet appliances are approved for use (3.1 meters) above any gravity air inlet (door, with the following vent sizes: 3”...
Page 12
Chimney Height Requirements - Site-Built Residential Home The vent termination height required is - USA, 1-foot minimum; Canada, 3-feet minimum above the roof penetration point as illustrated below (Ref. USA - National Standard, NFPA 211 and Canada National Standard CSA B365-01. Check with your local building offi cial for additional requirements for your area.
Page 13
Determining Size Of Pipe To Install To determine what diameter pipe to use in an installation (3” or 4”), fi rst 4 Inch Diameter Only fi nd the “equivalent pipe length” using the following guidelines, then plot this Figure and the altitude on the chart. Fill out the installation chart, and calculate your total equivalent pipe 3 or 4 Inch Diameter...
Page 14
Standard Horizontal Vent Installation 3. Push the stove with pipe attached towards the wall (the pipe will go through the wall thimble). Do not position the back of the stove closer than 2” (51 mm) from the wall (see Clearances, Page 6). Installing Free-Standing Pellet Stoves Models: Profi...
Page 15
Standard Horizontal Installation Confi gurations Profi le ® 20 FS-2 and Profi le 30 FS-2 3” (75 mm) Minimum 3” (75 mm) Minimum Top View Illustration clearance between wall clearance between Top View Illustration and pipe. If you vent to Top View Illustration wall and pipe.
Page 16
Preferred Installation – Vertical Vent Through the Roof Standard Vertical Installation Confi gurations ® Models: Profi le 20 FS-2 and Profi le 30 FS-2 This venting confi guration allows for the best stove performance. The These free-standing models may be connected to an existing fl ue or by vertical pipe promotes natural draft and with the chimney inside the installing listed type “PL”...
Page 17
Standard Installation Confi gurations Into an Existing Fireplace Model: Profi le 30 INS-2 ® Model: Profi le 30 INS-2 NOT ALLOWED IN CANADA IMPORTANT - Make sure the chimney and fi rebox are clean and free of soot and ashes before installation begins. Failure to do so may result in the transfer of soot into the room by way of the room air blower.
Page 18
Standard Installation Confi gurations Into an Existing Fireplace ® Model: Profi le 30 INS-2 IMPORTANT Make sure the chimney and fi rebox are clean and free of soot and ashes before installation begins. Failure to do so may result in the transfer of soot into the room by way of the room air blower. Model: Profi...
2, simply press the ON/OFF button once trim needs to be adjusted, contact an authorized to turn the appliance off, this will initiate the cool Lennox Hearth Products Technician to calibrate Control Board Operation down mode. The appliance can be restarted at internal software.
Page 20
When fi rst starting your pellet appliance, it will be necessary to prime the Fuel Delivery Rate auger. To prime the auger you need to fi rst fi ll the hopper with pellets, The heat select button manages the fuel delivery rate by controlling the and press the ON/OFF button on the control board.
Page 21
(see setting), this will ensure long life of the stove. Damper Location and Adjustment on Page If the overheating continues, contact your authorized Lennox Hearth Products dealer for more information. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE...
Clean Heat Exchange Tubes Only When The pellet sizes up to a maximum of 5/16” diam- PLEASE NOTE: Lennox Hearth Products has Appliance is Cool. eter. Different pellets may feed at considerably no control over the manufacturing of pellet fuel different rates.
Page 23
® (Model Profi le 20 FS-2 only) WARNING It may be easier to clean the tubes if the heat exchanger baffl e plate is DO NOT USE BRUSH ON HOT STOVE! removed fi rst (located in the fi rebox below exchange tubes). To remove, loosen the two screws holding the baffl...
Page 24
Accessing Ash Clean-Out Ports – Model: Profi le 30 FS-2 and Profi le 30 INS-2 (Recommended Frequency of 1 year) 1) Open fi rebox door. 2) Using a 5/16” nut driver, loosen the screws on the two clean-out covers (until screw heads will release through the key hole slots). Remove covers.
Page 25
® Ash Slide Plate (Profi le 20 FS-2 and Profi le 30 FS-2) Ash Pan (Profi le 30 INS-2) The Profi le 30 INS-2 has three ash pans (left side, right side and lower Ash that accumulates around the grate can be “dropped” into the ash center).
Page 26
Photoeye (All Models) Clean-Out ENSURE APPLIANCE IS COLD BEFORE BEGINNING As a part of normal maintenance, buildup of pellet debris (fi nes) must be periodically removed from the photoeye fi lter. This fi lter can be cleaned by following either procedure (A) or (B) on this page: Note: The photoeye views the fi...
Page 27
(B) Removing Photoeye Filter for Cleaning: 2. Clean Filter as follows: With the photoeye cover plate removed, look inside the opening. You will see an amber colored square glass fi lter 1. Lift off cover plate and turn over (the photoeye is attached to the inside secured in place by a bracket and 2 nuts.
Page 28
Motor Lubrication The blowers are permanently lubricated by the manufacturer. Do not apply oil to any part of the blower, doing so may cause damage. Remove side panel Rear Stove Compartment (All Models) retaining screw. The rear stove compartment should be cleaned periodically (a minimum of once a year).
Heat Select Button Thermal Switch, High Limit (L250-30F, N/C) COMPONENT DEFINITIONS There are 2 of these thermal switches on this This is the heat output control button. It controls model. If a temperature reaches 250° F., the power to the feed system - auger motor and high limit auto reset will “trip”...
) Change to a better grade of fuel if necessary. Check that the damper has been opened enough for the amount of fuel fed. ) Have Your Authorized Lennox Hearth Products dealer check your exhaust blower for proper operation. ) The venting system design is too restrictive...
Page 34
7. Stove will not light. A) The igniter element may have failed. A) Check igniter element fuse in rear stove compartment. Call your authorized Lennox Hearth Products dealer. See Lighting Procedure Without Igniter, Page 21. B) There is not enough pellets in the UltraGrate.
REPLACEMENT PARTS LIST DOOR PARTS AND BODY COMPONENTS Item Part No. / Cat. No. Description Stove Model 13640075 Clip Kit, Glass Bottom Profi le ® 20 FS-2 13640086 Clip Kit, Glass Right and Left Side Profi le 20 FS-2 14750264 Clip Kit, Glass Top Bottom (Doors w/ 3pc glass) Profi...
Page 36
REPLACEMENT PARTS LIST ELECTRICAL PARTS Item Part No. / Cat. No. Description Stove Model 18150150 Fuse, Control Board, 5 Amp, 250 volt, Fast blow, 12pk. 12150213 Igniter Assembly, Replacement, 380 Watts, 3.3 Amp.’s, 1 each(includes fuse holder w/fuse) 14750404 Photoeye Kit, Replacement 12058820 Power Cord, 8 feet 16050001...
Page 37
REPLACEMENT PARTS DIAGRAMS NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE...
Page 38
REPLACEMENT PARTS DIAGRAMS NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE...
Page 39
REPLACEMENT PARTS DIAGRAMS NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE...
Page 40
REPLACEMENT PARTS DIAGRAMS 3” NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE...
SEE YOUR MANUAL AND/OR DEALER FOR MORE INFORMATION. Manufacturer Listee: INPUT RATING RANGE: 1.5 TO 3.8 LBS./HOUR (NOMINAL) Lennox Hearth Products; 1110 W. Taft Ave.; ELECTRICAL RATING: 60 HZ, 115 V, LESS THAN 10 AMP Orange CA USA *60020146 REV E*...
Page 43
Manufactured Listee: A. BURN GRATE SPECIFIC INSTALLATION REQUIREMENTS. DO NOT ROUTE CORD BENEATH Lennox Hearth Products; 1110 W. Taft Ave.; B. HEAT EXCHANGER TUBES OR OVER APPLIANCE. THE INSERT MODEL MAY BE FRAMED INTO A WALL USING ZERO CLEARANCE KIT, CAT. NO. H0416.
OWNERSHIP RECORDS Dealer’s Name: Dealer’s Address: Zip Code: City: State: Date Installed: Serial Number: Date of Purchase: Notes: SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Description...
Page 47
NOTES NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE...