8.2 Commissioning work

Illustration
X4
X3
X3
46 | 76
X4
Original installation and operation manual
Description / explanation
1. Connect the voltage supply.
0 The BEKOMAT
carries out the power-on self-test.
®
2. Slowly pressurise the system (e.g. by slowly opening
the recommended shut-off valve [X4] in the
condensate inlet line [X3]).
3. Carry out a functional test (see "10.3.2 Functional test"
on Page 57).