0
297-2121-226
0
VINTAGE 05.01
0

RACKMOUNT DATA UNIT SPECIFICATIONS

0
The
following specifications apply to NT4X25AD /CH /AV rackmount
0
data units unless otherwise specified.
0

Mechanical Specifications

0
faceplate size
0
0
circuit card size
0
0
connectors
0

Electrical Specifications

0
inputs
0
0
0
ESD
0
0
fuse F1 (on circuit)
0
fuse F2 (on circuit)
0
fuse F3 (on circuit)
0

Environmental Specifications

0
operating temperature
0
storage temperature
0
relative humidity
0
0
MTBF
0

Regulatory Compliance

0
EMI
0
interconnect
0
0
3-40
8.75 in (21.5 cm) high
0.8 in (2 cm) wide
12.25 in (31 cm) long
6.8 in (17 cm) wide
backplane connector
+5 V dc @ 1.0 A
+12 V dc @ 0.1 A
-12 V dc @ 0.1 A
20 kV to the faceplate with no call drop
25 kV with no permanent damage
2 A
5 V rating
500 mA
12 V rating
500 mA
12 V rating
0
32 to 122 F (0 to 50 C)
0
-40 to 158 F (-40 to 70 C)
(operating) 95% non-condensing
0
(104 F)
greater than 10 years
FCC part 15 Class A computing device
CS-03 Issue 6
FCC Part 68
0
0
at
40 C
0