11.5. Adjustment Standard (Handset)
When connecting the simulator equipment for checking, please refer to below.
11.5.1. Component View
OSC
AF VOLT
METER
LOOP
Simulator
Dummy Base
Unit
(B).(C).(F)
Note:
(A) - (R) is referred to Check Point (Handset) (P.45)
(*1): when connecting with DECT Tester for measurement and/or adjustment it needs to short it.
AF
OSC
Connect between ANT-Short and ANT-Short GND (*1)
600
(I).(J)
PbF
REF-2
C1
Q9
R6
ANT -Short
ANT -Short-GND
C38
C81
C801
C91
R48
LCD_OTP
PNLB1219Y*-GW
C70
C71
C92
C93
JT AG
X1
IC3
IC1
KIN_3
RA5
CP2.8V
CP3V
R77
1.8V
R76
IC4
R104
CP4V
Q1
KIN_4
C866
POWER
CKM
STB_A
Q13
R105
Q6
RA1
R106
L74
STB_C
MIC+
SPM
MIC-
SPP
CHG_CTRL
Q4
Q2
URX
UTX
VBAT
GND
BATT -
BATT+
R7
D4
D5
CHG+
CHG-
A
C5
MIC+
MIC-
CHG+
CHG-
DC Power
5.5V
(D),(E)
61
KX-TG9581B/KX-TG9582B/KX-TGA950B
Green
Orange
56
Blue
56
Orange
2.8V
3.0V
(A).(M)
1.8V
(N).(O)
4.0V
100
2.2pF
MIC+
+
AF
+
Generator
MIC-
Power key
GND
DC POWER SUPPLY
2.6 - 2.25V
VBAT
(K)
(L)
(H)
(F).(G)