Panasonic KX-TG9581B Service Manual page 46

Hide thumbs Also See for KX-TG9581B:
Table of Contents

Advertisement

KX-TG9581B/KX-TG9582B/KX-TGA950B
Items
(F)*
Battery Monitor Check
(G)
Battery Low
Confirmation
(H)* BBIC Clock Adjustment
(I)*
Transmitted Power
Confirmation
(J)* RSSI Level Confirmation
(K)
Audio Check and
Confirmation
(L) SP phone Audio Check
and Confirmation
Check
Point
-
1. Apply 2.25 V between BATT+ and BATT-.
2. Execute the command
sendchar PAD
sendchar LED 0
sendchar CRX 0 1
sendchar AD1
It assumes that the return value is XX.
a) XX: 70: No need to adjust
b) XX: 66 ~ 6F: Need to adjust
XX: 71 ~ 7A: Need to adjust
Write AD value of 2.25 V to EEPROM.
ex) read data: XX = 6A, write data: YY = 6A
read data: XX = 73, write data: YY = 73
EEPROM = 0009(Low Voltage) write "YY"
Execute the command "wreeprom 00 09 01 YY".
EEPROM = 000A(No Voltage) write "YY -C"
Execute the command "wreeprom 00 0A 01 ZZ".
Note:
ZZ = YY - C
c) XX: 00 ~ 65: Reject
XX: 7B ~ FF: Reject
-
1. Apply 2.40 V between BATT+ and BATT-.
2. Confirm that there is no flashing of Battery Icon.
3. Apply 2.25 V ± 0.08 V between BATT+ and BATT-.
4. Confirm that there is flashing of Battery Icon.
CKM
1. Apply 2.6 V between BATT+ and BATT- with DC power.
2. Input Command "sendchar sfr", then you can confirm the current value.
3. Check X'tal Frequency. (10.368 MHz ± 100 Hz).
4. If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CKM
executing the command "sendchar sfr xx xx (where xx is the value)" so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
Note:
Clear the registered information for Base Unit before measurement, because the
Frequency will not possibly get stable due to the registered information.
Pressing the button of "3" "5" "7" "#"clears the registration.
Register to it on Base Unit after measurement.
-
Short Antenna pattern to GND.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: PP
• RFPI: 0102030405
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• RF LEVEL = -70 dBm
• PACKET: PP32Z
2. Execute the command "sendchar TST 01 02 03 04 05".
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is 19 dBm ~ 25 dBm.
-
Follow steps 1 to 3 of (I).
4.Execute the command "read RSSI"
5.Confirmed that the returned value is 21 A (hex)
-
1. Link to BASE which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 50 mA.
3. Input -45 dBm (600 Ω)/1 kHz to MIC of Handset. Measure the Level at Line I/F
and distortion level.
4. Confirm that the level is -3 dBm ± 5 dB and that the distortion level is < 5 % at
TEL Line (600 Ω Load).
5. Input -20 dBm (600 Ω)/1 kHz to Line I/F. Measure the Level at Receiver of
Handset and distortion level (Receive volume set to second position from
minimum).
6. Confirm that the level is -27 dBm ± 4 dB and that the distortion level is < 5 % at
Receiver (34 Ω Load).
-
1. Link to Base which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 50 mA.
3. Set the handset off-hook using SP-Phone key.
4. Input -30 dBm (600 Ω)/1 KHz to Line I/F and measure Receiving level at SP+
and SP-.
5. Confirm that the level is -7 dBm ± 3 dB and that the distortion level is < 5 %.
(vol = Max at SP (8 Ω Load))
Procedure
46
Check or
Replace Parts
IC1, F1, R45
IC1, F1, R45
IC1, X1, C47
IC1, C801,
C859, C860,
C861, C862
Refer to (I)
IC1, C12, RA7,
C11, C13,
MIC, R23,
C42, C70, C71
IC1, C72, C73,
C78, C79,
R76, R77

Hide quick links: