FU-24HSS010/N2-OUT
Procedure
1) Disconnect the wires connected to
the compressor. (Red wire connects
with PCB board, others connects with
terminals) (see CJ_ODU_008)
2) Disconnect the wires connected to
4-way valve. (see CJ_ODU_008)
3) Disconnect the wires connected to
the transformer. (see CJ_ODU_008)
4) Disconnect the other wires connected
to terminals. (see CJ_ODU_008)
5) Remove the PCB board. (see CJ_
ODU_008)
6) Remove the screws of the capacitors.
(see CJ_ODU_009)
Note: This sec�on is for reference only. Actual unit appearance may vary.
Illustra�on
Compressor
Transformer
Capacitor of Fan Motor
Fan Motor
4-Way Valve
CJ_ODU_008
Capacitor of compressor
CJ_ODU_009