Carrier Container Refrigeration Unit Operating Instructions Manual page 12

Carrier container refrigeration unit operating instructions
Table of Contents

Advertisement

Event
Trip Start (TS)
USDA Trip Comment
Pre-Trip Data
Economy Mode Start
(ECON_S)
Economy Mode End
(ECON_E)
ISO Trip Comment
Changed
Bulb Mode Start
(BULB_S)
Bulb Mode End
(BULB_E)
Controller Configuration
Change
Operating Mode Change Whenever unit changes
Power Management
Start
(Reciprocating Only)
Power Management End
(Reciprocating Only)
Airslide Position
Change
(Reciprocating Only)
Phase Switching
(Scroll Only)
Event
DataCORDER Alarm Ac-
tivity (DAL)
Battery Backup Start
(OFFWB)
Battery Backup End
(ONWB)
Power Loss (OFF)
Table 1-3. Temperature Controller Events - - Continued
When Event Occurs
Any time trip start is en-
tered
When entered with
interrogation device
Any time a Pre-Trip test is
completed and Controller
is configured to send indi-
vidual test data
Any time economy mode
is initiated
Any time economy mode
is terminated.
Whenever entered
Any time bulb mode starts
Any time bulb mode ends
Whenever changed by user Configuration information Last 1 per hour, last 1 per
mode
Whenever power manage-
ment starts
Whenever power manage-
ment ends
Whenever Makeup Vent
Slide Position is changed
Whenever Phase Sequence
is Checked
Table 1-4 DataCORDER Events
When Event Occurs
Case 1: Whenever an
alarm changes state
Case 2: At the end of any
hour where an alarm ac-
tive during that hour is in-
active at the end of the
hour
Loss of main power with
battery pack present
Restoration of AC power
with battery pack present
Loss of AC power with no
battery pack present
Data Sent
NA
Up to 80 bytes of custom-
er comment data
Pass/Fail for each sub-test,
and appropriate data points
for each test
NA
NA
Data entered by user
Evaporator fan speed,
DTT opening temperature,
dehumidification set point
NA
New operating mode
Power management mode
Method used to end power
management
Source of change com-
mand
Phase switched to correct/
incorrect
Data Stored
Case 1: Alarms active
during this hour
Case 2: Currently active
alarms
NA
NA
NA
1-7
Limits
NA
Last 1 per day
Unlimited
NA
NA
Last 1 per hour, last 1 per
day
NA
NA
day
Last 2 per hour, last 24 per
day
Last 4 per hour, last 24 per
day
Last 4 per hour, last 24 per
day
Last 1 per hour, last 6 per
day
Last 6 per hour, last 24 per
day
Limits
Case 1: 1 per hour which
is a combination of all
events in that hour
Case 2: 1 per hour
NA
NA
NA
62-02575-07