SECTION 3: Command Centre Screen

3.5.6 Quiet mode

Lowering the fan speed can reduce noise. Increasing it
may improve chilling performance.
Residential models: 75% / 100% / Auto (default).
Commercial models: 100% (default) / Auto.

3.5.7 Advanced settings 1

Periodic Pulse Reduced Cavitation Mode
Hot setpoint must be < 98°C to disable
Pre-pulse Reduced Cavitation Mode
Adds slight delay to boiling dispense
Power Pulsing Mode
Hot setpoint must be < 98.5°C to disable
Periodic Pulse Reduced Cavitation Mode
Sends two electric pulses every 5 minutes to the pump.
This prevents the build-up of air bubbles inside the pump
to ensure an even flow of hot water at the tap.
Pre-Pulse Reduced Cavitation Mode
Pulses immediately before boiling dispense to prevent the
build-up of air bubbles inside the pump and ensure an even
flow of hot water at the tap. There will be a 150 millisecond
delay before water is dispensed.
Power Pulsing Mode
Applies a closer tolerance to the set temperature, to
ensure hot water is maintained as closely as possible to the
set point.
806835NZ v1.05 03.22 G5 User guide
ADVANCED SETTINGS 1