Indoor/Outdoor Connection Cables
1. Open and lift the front panel. See Page 14 Figure 5
(a).
2. Remove the screw from the covering plate on the
terminal board.
3. Pass the power cable through a separate cable duct
on the back of the indoor unit and pull it out from the
front.
4. Connect the neutral wire coming from the power
cable to the "N" (1) terminal on the terminal board;
connect the signal wire to the "2" terminal; connect
the live wire to the "3" terminal; connect the "ground"
wire to the ground terminal. See Figure 8.
5. Plug the power cable with protective pipe into the
pressing groove and close the cover place. Tighten
fixing screws in place to clamp de connecting cable.
6. Install the front panel back into position.
Notes:
If the connecting power cable is not long enough, contact your local service provider to obtain a longer cable.
No union sections are allowed in the middle of the cable.
Be sure to connect the cable correctly, otherwise it could cause failure in some electrical parts.
Tighten the terminal screw securely.
After tightening the screw, pull gently on the cable to ascertain it's integrity.
Incorrect connection of the grounding cable may cause electric shock.
Be sure to place the cover plate securely in its place and press it closely against the connecting cable. Improper
placemente of the junction box cover place may allow dust or water to penetrate and expose the connections
terminal directly to external forces, which could provoke fire or electric shock.
MS-SVX10A-EN
Installation Indoor Unit
24
Covering Plate
Power
Cord
Figure 7
Terminal Board
Ground
Cable Groove
Power Cable
Figure 8