Belt - Hoover Windtunnel UH70120 Owner's Manual

Hoover windtunnel series vacuum cleaner operating and servicing instructions
Table of Contents

Advertisement

Available languages

Available languages

belt

CAUTION
!
To reduce the risk of injury from moving parts,
unplug vacuum before servicing.
The belt is located under the bottom plate of the
vacuum and should be checked from time to time to
be sure it is in good condition.
when to replace
Replace belt if it is stretched, cut or broken.
To check the Stretch belt, refer to Fig. 4.22 - 4.24.
how to replace
4.19 Turn vacuum over so bottom side is facing up.
Rotate red upper latch (A) counter clockwise.
4.20 Slide red lower latch (B) to the unlock position.
4.21 Lift off bottom plate.
4.22 Remove used belt from brushroll (C) then from
motor shaft (metal rod) (D) and discard.
stretch belt: what to buy
Use only genuine HOOVER
vacuum. When purchasing a new belt, ask for
Stretch Belt - HOOVER
4.23 With lettering on outside of belt, slide new belt
over motor shaft (metal rod) (E), then slip around
area of brushroll without bristles (F).
With belt in place, pull and slide brushroll into nozzle
making sure that the brushroll end caps are in the
correct orientation.
IMPORTANT
Rotate brushroll manually to make sure belt is
not twisted.
4.24 Reposition bottom plate, aligning tabs along
front edge of nozzle guard with slots in nozzle.
Rotate back into position. Slide red lower latch to
Lock position, and rotate red upper latch clockwise.
!
belts with your
®
part no. 38528033.
®
4.19
A
4.21
4.23
12
4.20
b
4.22
4.24
e
F
d
C

Hide quick links: