Hoover UH72630 - PET UPRIGHT VACUUM Manual

Hoover UH72630 - PET UPRIGHT VACUUM Manual

Also See for UH72630:

Advertisement

Hoover UH72630 - PET UPRIGHT VACUUM Manual

PRODUCT ASSEMBLY

CARTON CONTENTS


Fig (1.1)

  1. Handle
  2. Vacuum Base
  3. Pet Turbo Tool/Turbo Tool*
  4. Crevice Tool
  5. Telescoping Wand
  6. Screw (for assembly)
  7. Dirt Cup
  8. Pet Upholstery Tool*

Articulating Upholstery Tool*

  1. Articulating Dusting Tool*
  2. Extra Filter*

*Varies per model

Remove all parts from carton and identify each item shown
Make sure all parts are located before disposing of packing materials
Additional parts may be ordered at Hoover.com or call 1 800 944 9200

ATTACH HANDLE

Note: Remove the screw located in the vacuum base and set aside until instruction 1.3


1.2 Insert handle section into vacuum base Push down firmly


1.3 Using a Phillips screwdriver fasten (1) screw behind handle into vacuum base

ATTACH DIRT CUP


1.4 Place bottom of dirt cup into vacuum body first Pivot cup into vacuum Dirt cup is secure when you hear a click

POSITION TOOLS

(varies per model)


1.5 Attach bottom of Turbo Tool (A) and pivot into Air powered Tool Clip until secure


1.6 Place Crevice Tool into Wand and slide into tool storage area on left back side (B) of vacuum and place Upholstery Tool or Articulating Tool on right back side (C) of vacuum as shown

Actual model may vary from images shown.

HOW TO USE

PRODUCT DESCRIPTION

PRODUCT DESCRIPTION
(Fig 2.1)

  1. Handle
  2. ON/OFF Switch
  3. Dirt Cup Release Button
  4. Carry Handle
  5. Dirt Cup
  6. Stair Cleaning Handle
  7. Headlight*
  8. Height Adjustment
  9. Furniture Guard
  10. Brushroll On/Off Pedal
    (Suction Only Mode)
  11. Filter made with HEPA media and Carbon Filter* Access
  12. Rinsable Filter Access
  13. System Check Indicator
  14. Turbo Tool **
  15. Crevice Tool (inside wand)
  16. Telescoping Wand
  17. Hose
  18. Handle Release Pedal
  19. Hose Tube
  20. Hose Release Button
  21. Dusting/ Upholstery Tool**
  22. Cord
  23. Air Valve Dial

*Available on select models only
**Varies per model

ON-OFF SWITCH


2.2 Plug cord into electrical outlet

To turn vacuum ON push ON/OFF switch once
To turn vacuum OFF push switch again

SUCTION ONLY MODE/BRUSHROLL SHUT-OFF

for bare floors and very high pile carpet

2.3 For optimal cleaning performance on bare floors and carpet with pile deeper than 1 brushroll should be turned off

The vacuum is shipped with the brushroll in the ON position. To turn brushroll OFF for Suction Only Mode step on pedal (A).


Pedal (A) is inactive when the cleaner is in the upright position.


Brushroll should be in off position for cleaning of high pile carpet deeper than 1


Not to be used for grooming a pet

TRANSPORTING CLEANER


2.6 To move your cleaner from room to room put handle in upright position tilt cleaner back on rear wheels and push forward.

HANDLE POSITIONS

2.7 The handle of your cleaner has two positions:

  1. Upright for storage and when using cleaning tools.
  2. Operating position for general operation on carpets and floors. Step on handle release pedal to lower handle.

CARPET HEIGHT ADJUSTMENT

CARPET HEIGHT ADJUSTMENT
2.8 To adjust height setting TURN knob (A) to desired height setting

For maximum cleaning performance the following carpet height settings are recommended:

  • Barefloor setting (1): for bare floors
  • Low setting (2): for all types of carpet
  • Higher settings: for very deep pile carpet where easier pushing effort is desired while maintaining good cleaning performance


If the vacuum is difficult to push turn knob to the next higher setting

AIR VALVE DIAL


2.9 To operate dial TURN dial (A) to desired position until it clicks
HOSE position is for cleaning with hose and/or tools
FLOOR position is for general floor cleaning thru nozzle


Vacuum will only pick up debris by the Hose/ Tools when the valve dial is placed into "HOSE position. Valve dial must be returned to "FLOOR position in order to pick up debris thru the floor Nozzle.

Actual model may vary from images shown.

TOOLS

Tools allow for cleaning surfaces above the floor and for reaching hard to clean areas.
The vacuum is ready for tool use when handle is in upright position.

SELECT PROPER TOOL

(Tools may vary per model)

SELECTING PROPER TOOL
(Fig 3.1)

  1. Use Upholstery Tool to clean upholstered furniture and carpeted stairs
  2. Turbo Tool may be used for upholstered furniture and carpeted stairs
  3. Telescoping Wand is used to give extra length to your hose
  4. Crevice Tool may be used in tight spaces corners and along edges
  5. Articulating Tool may be used to clean hard to reach areas such as ceiling fans and bookshelves

REMOVING HOSE


3.2 When using cleaning tools place cleaner handle in the upright position. The agitator brushroll will not rotate when the cleaner is in the upright position.

To remove hose for tool use press the hose release button and pull hose end out.
To lock back into place push hose into hose tube until you hear a click


3.3 Set air valve for desired use Hose/Floor
Turn valve back counterclockwise to FLOOR position until it clicks (A)


Vacuum will only pick up debris by the Hose/Tools when the valve dial is placed into "HOSE" position. Valve dial must be returned to "FLOOR" position in order to pick up debris thru the floor Nozzle

ATTACH WAND AND TOOLS

(Tools may vary per model)


Unplug before connecting Air Powered Hand Tool


3.3 Attach tool or wand to the hose (A).
Attach tool to wand (B) by pushing it firmly onto the wand.

Twist wand or tool slightly to tighten or loosen the connection.
To extend wand twist counter clockwise to the unlocked position extend wand & twist clockwise until tight. Reverse to collapse


Not to be used for grooming a pet

HOW TO CLEAN TOOLS

To clean Hose and Turbo Tool wipe with a damp cloth. DO NOT submerge in water.
Other cleaning tools may be washed in warm water with a mild detergent. Rinse and air dry 24 hours before using

Actual model may vary from images shown.

STAIR CLEANING


3.4 Lift vacuum by Stair Cleaning Handle and position on stairs. Clean forward to back. Never leave the vacuum standing on stairs when not cleaning.


3.5 Use the Hose and Turbo Tool (Tool varies per model) for stair cleaning. When using tools always ensure handle is in upright position


Use extra care when cleaning on stairs. To avoid personal injury or damage and to prevent the cleaner from falling always place cleaner at bottom of stairs on floor. Do not place cleaner on stairs or furniture as it may result in injury or damage. When using tools always ensure handle is in upright position

CORD STORAGE


3.6 Wrap cord around hooks for convenient storage. Attach the plug end to the cord.

MAINTENANCE

Familiarize yourself with these home maintenance tasks as proper use and care of your vacuum will ensure continued cleaning effectiveness.
If appliance is not working as it should has been dropped damaged left outdoors or dropped into water take it to a service center prior to continuing use.

4.1 The System Check ndicator located at (A) alerts you to possible system performance issues.

PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
If System Check indicator is red:
  1. Rinsable filter and/or filter made with HEPA media is dirty
  2. Dirt cup is full and/or clogged
  3. Brushroll and/or hose is clogged
  4. Valve dial may be partially turned and not in proper mode
  1. Clean rinsable filter and/or filter made with HEPA media, reference "Filter Made With HEPA Media"
  2. Empty dirt cup, reference "DIRT CUP"
  3. Check hose for clogging, reference "HOW TO CLEAN HOSE"
    Check brushroll for clogging, reference "HOW TO CLEAN BRUSHROLL"
  4. Turn valve dial to HOSE or FLOOR mode, reference "AIR VALVE DIAL"

Any other servicing should be done by an authorized service representative

warning NOTICE
A Thermal Protector has been designed into your cleaner to protect it from overheating. When the thermal protector activates the cleaner will stop running.
If this happens proceed as follows:

  1. Turn cleaner OFF and unplug it from the electrical outlet
  2. Empty dirt cup
  3. Inspect the nozzle inlet hose connector hose dirt cup inlet cyclonic filter rinsable filter and HEPA filter for any obstructions. Clear obstructions if present.

When cleaner is unplugged and motor has cooled for 30 minutes the thermal protector will deactivate and cleaning may continue.
If the thermal protector continues to activate after following the above steps your cleaner needs servicing.

DIRT CUP

When to Empty


4.2 To maintain optimal performance empty the dirt cup before the dirt cup reaches the max line (A). Place the vacuum in the upright position before removing the dirt cup.


To reduce the risk of personal injury. Unplug before cleaning or servicing. Do not use vacuum without dirt cup or filters in place.
Very fine materials such as face powder or cornstarch may seal the filter and cause a reduction in performance. When using the vacuum for this type of dust empty the cup and clean the filters often.

How to Empty


4.3 Press dirt cup release button (A) and pivot cup out.


4.4 Hold dirt cup over trash receptacle push dirt cup door release lever (B) to open dirt cup door (C).
Close dirt cup door (C). Press firmly to secure at front (D).


4.5 Place bottom of dirt cup into vacuum body first. Pivot dirt cup into vacuum body and press firmly until it locks into place.

FILTERS

When to Clean

To maintain optimal performance filters should be cleaned at least every two months under normal use.

Rinsable Filter

How to Clean:
Remove dirt cup as described in Fig 4.3


4.6 Pull up on dirt cup latch to open


4.7 Pull on filter by the pocket to remove rinsable filter.
Hold filter under running water for at least two minutes to remove dirt and debris. Squeeze filter twice while underwater. Remove from water and squeeze a final time to remove excess water.


Allow filter to dry completely before replacing. Dry filter on edge so air circulates on both sides of filter. This may take up to 48 hours.

Replace filter with pocket and graphics facing up.
Close lid securely by pushing until it clicks.
Replace dirt cup as described in Fig 4.5


To reduce the risk of personal injury. Unplug before cleaning or servicing. Do not use vacuum without dirt cup or filters in place

What to Buy:
When used and maintained properly your Rinsable Filter should not need replacement within the warranty period if desired additional filter is available at Hoover.com or call 1 800 944 9200 Ask for Hoover Part No. 304087001

Filter Made With HEPA Media

How to Clean:
4.8 With fingers in slots pull filter frame (A) straight out. Hold filter over a trash receptacle and tap out dirt and debris.
Slide back into position on vacuum.


To reduce the risk of personal injury. Unplug before cleaning or servicing. Do not use vacuum without dirt cup or filters in place.


DO NOT RINSE OR WASH THE FILTER MADE WITH HEPA MEDIA

What to Buy:
When used and maintained properly your Filter should not need replacement within the warranty period if desired additional filter is available at Hoover.com or call 1 800 944 9200 Ask for Hoover Part No. 305687001 Actual model may vary from images shown.

Carbon Filter

How to Clean:
(Available on select models only).
Your Carbon Filter is located on the underside of the Filter made with HEPA media


DO NOT RINSE OR WASH the Carbon Filter

What to Buy:
Carbon Filter may need to be replaced more often to maintain optimal odor absorbing effectiveness. Additional filter is available at Hoover.com or call 1 800 944 9200 Ask for Hoover Part 902404001

Cyclonic Filter Assembly


To reduce the risk of personal injury. Unplug before cleaning or servicing. Do not use vacuum without dirt cup or filters in place.

How to Clean:
Remove dirt cup as described in Fig 4.3


4.9 Twist filter assembly (A) counter clockwise. Remove assembly from dirt cup


4.10 Dirt and debris can be cleaned from the filter assembly with the Dusting/Upholstery Tool


4.11 If further cleaning of the internal filter assembly is required turn dust skirt (B) counterclockwise to remove


4.12 Grab dirt cup shroud (C) pull straight off and clean with dusting/upholstery tool.

After cleaning replace dirt cup shroud (C) onto inside edge of filter assembly and align. Place skirt (B) onto shroud align (4) slots with (4) tabs and turn clockwise to lock.

Place the filter assembly (4.9 A) on the dirt cup aligning (3) tabs on filter with (3) slots on dirt cup (B) and twist it clockwise to secure into position.

Replace dirt cup as described in Fig 4.5.

HOW TO CLEAN BRUSHROLL

To reduce the risk of injury from moving parts. Unplug before servicing.


4.13 Turn vacuum over so bottom side is facing up and remove the (6) screws (A).


4.14 Pivot out bottom plate away from hidden latch (B) and remove any debris and/or hair from the brushroll.


4.15 Reposition bottom plate aligning latch (B) and fastening all (6) screws (A). Press firmly at latch (B) area to ensure that it is properly latched.

Actual model may vary from images shown.

HOW TO CLEAN HOSE


To reduce the risk of personal injury. Unplug before cleaning or servicing.


4.16 To remove hose for tool use press the hose release button (A) and pull hose end out.

Clear away debris or obstructions from hose. Do not use sharp objects to clean out hose as they can cause damage. To lock back into place push hose into hose tube until you hear a click.

HOW TO CLEAN TURBO TOOL

(Tool varies per model)


To reduce the risk of injury from moving parts.
Unplug vacuum before servicing.


4.17 Clean the Turbo Tool by removing the two screws (A) located on the bottom cover with a Phillips head screwdriver.


4.18 Remove the bottom cover (B).
Clean out any debris or hair from the brushroll and turbine fan.


4.19 Replace the bottom cover insert and tighten the (2) screws.

HEADLIGHT

How to Replace

(available on select models only)


To reduce the risk of electric shock. Unplug before cleaning or servicing.

Removing Lens

Press Handle Release Pedal and place handle in low position


4.20 Using a Phillips screwdriver remove (2) screws as shown and lift off lens.

Installing Bulb


4.21 Pull old bulb straight out of socket Push new bulb straight into socket until locked in place.

Do not use excessive force when installing bulb.
Do not twist or turn bulb when installing bulb

Replacing Lens


4.22 Reposition lens and secure with screws

What to Buy

Additional bulbs may be ordered at Hoover.com or call 1 800 944 9200 Ask for Hoover Part No. 27313-107.

Actual model may vary from images shown.

BELT


To reduce the risk of injury from moving parts.
Unplug before servicing.

The belt is located under the bottom plate of the vacuum and should be checked from time to time to be sure it is in good condition

When To Replace

Replace belt if it is stretched cut or broken.
To check the belt refer to Fig 4.26-4.28

How To Replace


4.23 Turn vacuum over so bottom side is facing up and remove the (6) screws (A)


4.24 Pivot out bottom plate away from hidden latch (B)


4.25 Remove used belt from brushroll (C) then from motor shaft (metal rod) (D) and discard

What to Buy

Use only genuine HOOVER belts with your vacuum.
When purchasing a new belt for models with Brushroll On/Off (Suction Only Mode) ask for Flat Belt HOOVER part No. 562289001 or AH20065
If desired additional belts can be purchased at Hoover.com or 1 800 944 9200


4.26 With lettering on outside of belt slide new belt over motor shaft (metal rod) (E)


4.27 Remove any debris and/or hair from the brush roll. Then slip other end of belt around area of brushroll without bristles (F). With belt in place pull and slide brushroll into nozzle making sure that the brushroll end caps are in the correct orientation


4 28 Reposition bottom plate aligning latch (B) and fastening all (6) screws (A).
Press firmly at latch (B) area to ensure that it is properly latched


Rotate brushroll manually to make sure belt is not twisted

LUBRICATION

The motor and brushroll are equipped with bearings which contain sufficient lubrication for their lifetime.
The addition of lubricant could cause damage. Do not add lubricant to motor or brushroll.

TROUBLESHOOTING

If a minor problem occurs it usually can be solved quite easily when the cause is found by using the checklist below.
Any other servicing should be done by an authorized service representative.
If appliance is not working as it should has been dropped damaged left outdoors or dropped into water take it to a service center prior to continuing use.


To reduce the risk of personal injury.
Unplug before cleaning or servicing.

PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION

The device won't run

  1. Power cord not firmly plugged into outlet
  2. Blown fuse or tripped breaker
  3. Thermal Protector activated
  1. Plug unit in firmly
  2. Check fuse or breaker in home Replace fuse/reset breaker in home
  3. Unplug and allow vacuum to cool for 30min (This will reset the thermal protector)

System Check Indicator has turned red

or

The unit won't pick up

or

Low suction

  1. Rinsable Filter and/or Filter made with HEPA media is dirty
  2. Dirt cup full and/ or clogged
  3. Broken or worn belt
  4. Brushroll and/ or Hose clogged
  5. Carpet height setting is incorrect
  6. Suction Only Mode is ON
  7. Valve dial may be partially turned and/or not in proper mode
  1. Clean Rinsable Filter and or Filter made with HEPA media, "FILTERS"
  2. Empty dirt cup, "DIRT CUP"
  3. Replace belt, "BELT"
  4. Check Hose, "HOW TO CLEAN HOSE"
    Check Brushroll, "HOW TO CLEAN BRUSHROLL"
  5. Set Carpet Height Adjustment to appropriate setting for carpet being cleaned, "CARPET HEIGHT ADJUSTMENT"
  6. Step on Brushroll ON/OFF Pedal to turn Suction Only Mode OFF, "SUCTION ONLY MODE/BRUSHROLL SHUT-OFF"
  7. Turn valve dial to FLOOR or HOSE mode, "AIR VALVE DIAL"

Dust escaping from the unit

  1. Dirt cup full
  2. Dirt cup not installed correctly
  3. Hose not installed correctly
  4. Rinsable and/or Filter made with HEPA media not installed completely
  1. Empty dirt cup, "DIRT CUP"
  2. Review Dirt Cup removal & replacement, "DIRT CUP"
  3. Review Hose installation, "REMOVING HOSE"
  4. Review Filter Removal and Cleaning, "FILTERS"

Headlight not working

  1. Bulb burnt out
  2. Loose electrical wires
  1. Replace bulb, "Installing Bulb"
  2. Call 1 800 944 9200 for nearest authorized Hoover dealer

Device is difficult to push or won't move forward

  1. Carpet height setting is incorrect
  2. Brushroll is activated
  1. Set Carpet Height Adjustment knob to appropriate setting for carpet being cleaned, "CARPET HEIGHT ADJUSTMENT"
  2. For very high pile carpet deeper than 1 turn brushroll off

Turbo Tool brushroll won't turn

  1. Too much pressure being applied to tool
  2. Blockage
  3. Low vacuum suction
  4. Valve dial may be partially turned and/or not in proper mode
  1. Continue using tool applying light pressure
  2. Remove blockage
  3. Check items under "The unit won t pick up or Low suction"
  4. Turn valve dial to FLOOR or HOSE mode, "AIR VALVE DIAL"

Smoky/burning smell detected

  1. Belt broken or stretched
  2. Brushroll is clogged
  1. Replace brushroll belt, "BELT"
  2. Clear/remove debris from brushroll, "HOW TO CLEAN BRUSHROLL"

SERVICE

To obtain approved Hoover service and genuine Hoover parts locate the nearest Authorized Hoover Warranty Service Dealer (Depot) by:

  • Checking the Yellow Pages under "Vacuum Cleaners or "Household"
  • Visit our website at hoover.com (U.S. Customers) or hoover.ca (Canadian customers).
    Follow the service center link to find the service outlet nearest you
  • For an automated referral of authorized service outlet locations call 1 800 944 9200

Do not send your vacuum to Hoover nc Company in Glenwillow for service. This will only result in delay.
If you need further assistance:
To speak with a customer service representative call 1 800 944 9200; Mon Fri 8am 7pm EST. Always identify your vacuum by the complete model number when requesting information or ordering parts (The model number appears on the bottom of the vacuum )
PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE

WARRANTY

For an automated referral to authorized service outlets in the U.S.A phone: 1 800 944 9200 OR visit Hoover online at www.hoover.com.
For additional assistance or information concerning this Warranty or the availability of warranty service outlets phone the Hoover Consumer Response Center Phone 1 800 944 9200 Mon Fri 8am 7pm EST.

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE.

burn hazardburn hazard
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:

  • Fully assemble before operating.
  • Operate cleaner only at voltage specified on data label on back of cleaner.
  • Do not leave appliance when plugged in. Unplug from outlet when not in use and before cleaning or servicing.
  • Do not use outdoors or on wet surfaces.
  • Do not allow to be used as a toy. Not intended for use by children age 12 and under. Close supervision is necessary when used near children. To avoid injury or damage, keep children away from product, and do not allow children to place fingers or other objects into any openings.
  • Use only as described in this manual. Use only manufacturer's recommended attachments and products.
  • Do not use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, take it to a service center prior to continuing use.
  • Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not place product on cord. Do not run appliance over cord. Keep cord away from heated surfaces.
  • Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
  • Do not handle plug or appliance with wet hands.
  • Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow.
  • Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
  • Turn off all controls before unplugging.
  • Use extra care when cleaning on stairs. To avoid personal injury or damage, and to prevent the cleaner from falling, always place cleaner at bottom of stairs on floor. Do not place cleaner on stairs or furniture, as it may result in injury or damage.
  • Do not use to pick up flammable or combustible liquids, such as gasoline, or fine wood sandings, or use in areas where they may be present.
  • Unplug before connecting Turbo Tool.
  • Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
  • Do not use without Dirt Cup and/or Filters in place.

  • This product contains chemicals known to the State of California to cause cancer, birth defects or reproductive harm. WASH HANDS AFTER HANDLING.


TO REDUCE THE RISK OF DAMAGE:

  • Avoid picking up hard, sharp objects with this product, as they may cause damage.
  • Store appropriately indoors in a dry place. Do not expose machine to freezing temperatures.
  • Do not use sharp objects to clean out hose as they can cause damage.
  • With brushroll on, do not allow cleaner to sit in one location for an extended period of time, as damage to floor can result.

  • To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.

Be sure to register your product online at Hoover.com or call 1 800 944 9200 to register by phone. Visit Hoover.com for additional video instructions for assembly and maintenance

If you need assistance:
Visit our website at hoover.com. Follow the authorized dealer locator link to find the Hoover authorized dealer nearest you or call 1 800 944 9200 for an automated referral of Hoover authorized dealer locations (U.S. only) or to speak with a customer service representative; Mon Fri 8am 7pm EST
PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Hoover UH72630 - PET UPRIGHT VACUUM Manual

Advertisement

Need Assistance?

Do you have a question about the UH72630 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents