Trigger Commands; Resetting The Standard Product Defaults - Hand Held Products 2020/5620 System Manual

Cordless system
Table of Contents

Advertisement

Example #4: What are the device's settings for all Codabar selections?
Enter:
cbr?.
Response:
CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device's Codabar Coding Enable (CBRENA) is
set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don't Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.

Trigger Commands

You can activate and deactivate the scanner with serial trigger commands.
First, the scanner must be put in Manual/Serial Trigger Mode either by scanning
the Manual/Serial Trigger Mode bar code
Serial Menu Command
the trigger is activated and deactivated by sending the following commands:
Activate:SYN T CR
Deactivate:SYN U CR
The scanner scans until a bar code has been read, until the deactivate com-
mand is sent, or until the serial time-out has been reached (see
(Serial Trigger Mode)
page
10-9).

Resetting the Standard Product Defaults

If you aren't sure what programming options are in your scanner, or you've
changed some options and want the factory settings restored, scan the
Standard Product Default Settings bar code below.
The chart on the following pages lists the factory default settings for each of the
menu commands (indicated by an asterisk (*) on the programming pages).
10 - 4
(page
10-9). Once the scanner is in serial trigger mode,
on page 3-4 for a description, and the serial command on
Standard Product Default Settings
IMAGETEAM™ 2020/5620 System Manual
(page
3-4), or by sending the Manual/
Read Time-Out

Advertisement