MCA
— Minimum Circuit Amps
MOCP — Maximum Overcurrent Protection (Amps)
*Sizes shown are for single-point connection of electric heat acces-
sory and air handler.
HEATER RATING
VOLTAGE
200
240
.694
480
575
NOTE: The following equation converts kW of heat energy to Btuh:
kW x 3.412 = Btuh.
UNIT
40RMQ
CAELHEAT002A00
CAELHEAT001A00
CAELHEAT005A00
CAELHEAT004A00
CAELHEAT008A00
CAELHEAT007A00
CAELHEAT011A00
CAELHEAT010A00
008
CAELHEAT014A00
CAELHEAT013A00
CAELHEAT017A00
CAELHEAT016A00
CAELHEAT020A00
CAELHEAT019A00
CAELHEAT023A00
CAELHEAT022A00
LEGEND
MCA
— Minimum Circuit Amps
MOCP — Maximum Overcurrent Protection (Amps)
*Sizes shown are for single-point connection of electric heat acces-
sory and air handler.
HEATER RATING
VOLTAGE
230
400
898
Table 5A — Accessory Electric Heater Data (60 Hz)
HEATER
V-PH-Hz
PART NO.
240-3-60
480-3-60
575-3-60
240-3-60
480-3-60
575-3-60
240-3-60
480-3-60
575-3-60
240-3-60
480-3-60
575-3-60
240-3-60
480-3-60
575-3-60
ACTUAL HEATER VOLTAGE
208
230
240
400
440
.751
.918
1
.694
.840
Table 5B — Accessory Electric Heater Data (50 Hz)
HEATER
V-PH-Hz
PART NO.
400-3-50
230-3-50
400-3-50
230-3-50
400-3-50
230-3-50
400-3-50
230-3-50
400-3-50
230-3-50
400-3-50
230-3-50
400-3-50
230-3-50
400-3-50
230-3-50
ACTUAL HEATER VOLTAGE
220
230
240
.915
1.0
1.084
NOMINAL kW
5
10
15
25
35
NOTES:
1. MCA and MOCP values apply to both standard and alternate factory-
supplied motors.
2. Electrical resistance heaters are rated at 240 v, 480 v, or 575 v. To
determine heater capacity (kW) at unit nameplate voltage, multi-
ply 240-v, 480-v, or 575-v capacity by multipliers found in table
below.
460
480
550
575
600
.918
1
.915
1
1.089
NOMINAL kW
3.47
4.59
6.94
9.18
10.42
13.78
17.36
22.96
24.31
32.14
6.94
9.18
13.89
18.37
20.83
27.55
NOTES:
1. MCA and MOCP values apply to both standard and alternate factory-
supplied motors.
2. Electrical resistance heaters are rated at 230 v or 400 v. To de-
termine heater capacity (kW) at unit nameplate voltage, multiply
230-v or 400-v capacity by multipliers found in table below.
380
400
415
0.903
1.0
1.076
8
HEATER
MCA*
AMPS
12.0
25.6
6.0
12.3
5.0
11.9
24.1
40.7
12.0
19.8
10.0
18.1
36.0
55.7
18.0
27.4
15.1
24.4
60.1
85.8
30.1
42.4
25.1
67.0
84.0
115.8
42.1
57.4
35.1
49.5
HEATER
MCA*
AMPS
5.0
11.1
11.5
25.0
10.0
17.3
23.1
39.5
15.0
23.6
34.6
53.9
25.1
36.2
57.6
82.6
35.1
48.7
80.7
111.5
10.0
23.0
23.1
39.5
20.0
35.5
46.1
79.9
30.1
48.1
69.2
108.7
MOCP*
30
15
15
50
25
25
80
40
35
125
60
50
175
80
70
MOCP*
15
30
25
50
30
80
50
110
70
175
30
50
50
110
70
150

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents