Goodman SS-CPG180-240 Specifications page 19

Cpg commercial 15- & 20-ton, three-phase packaged gas/electric units

Advertisement

Cpg180/240***4B/7B*** T
w
d
iring
iagram
SUPPLY VOLTAGE
SUPPLY VOLTAGE
460-575/3/60
460-575/3/60
460V OR 575V
460V OR 575V
1
1
CCH1
2
2
1
1
CCH2
2
2
1
1
1
1
TB1
TB1
S1
S1
S2
S2
NOTE 3
NOTE 3
L1
L1
24V
24V
1
1
FS
FS
F
F
C
C
H
H
D1
D1
4
4
LS
LS
5
5
ALS
ALS
3
3
IIC
IIC
6
6
PS
PS
8
8
ECON
ECON
9
9
2
2
7
7
10
10
12
12
LPS1
LPS1
HPS1
HPS1
11
11
6
6
CCHR1
CCHR1
NOTE 5
NOTE 5
Y1
Y1
R
R
G
G
W1
W1
W2
W2
TO THERMOSTAT
TO THERMOSTAT
INSTALLER/SERVICEMAN
INSTALLER/SERVICEMAN
THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:
STATUS LIGHT
STATUS LIGHT
EQUIPMENT STATUS
EQUIPMENT STATUS
ON
ON
NORMAL OPERATION
NORMAL OPERATION
NO POWER OR
NO POWER OR
OFF
OFF
INTERNAL CONTROL
INTERNAL CONTROL
IGNITION FAILURE
IGNITION FAILURE
OPEN ROLLOUT
OPEN ROLLOUT
1 BLINK
1 BLINK
SWITCH
SWITCH
OPEN AUX. LIMIT
OPEN AUX. LIMIT
SWITCH
SWITCH
PRESSURE SWITCH
PRESSURE SWITCH
2 BLINKS
2 BLINKS
OPEN
OPEN
PRESSURE SWITCH CLOSED
PRESSURE SWITCH CLOSED
3 BLINKS
3 BLINKS
WITHOUT INDUCER ON
WITHOUT INDUCER ON
4 BLINKS
4 BLINKS
OPEN LIMIT SWITCH
OPEN LIMIT SWITCH
FALSE FLAME SENSED
FALSE FLAME SENSED
5 BLINKS
5 BLINKS
COMPRESSOR
COMPRESSOR
6 BLINKS
6 BLINKS
OUTPUT DELAY
OUTPUT DELAY
SS-CPG180-240
1
1
3
3
VM
VM
3
3
460V OR 575V
460V OR 575V
TR
TR
3
3
TR
TR
NOTE 3
NOTE 3
L2
L2
IGN
IGN
IIC
IIC
FS
FS
BC
BC
4
4
6
6
VMR
VMR
RS
RS
GV
GV
CC2
CC2
LPS2
LPS2
HPS2
HPS2
CC1
CC1
4
4
6
6
4
4
CCHR2
CCHR2
PLF
PLF
9
9
3
3
6
6
Y
Y
NOTE
NOTE
8
8
5
5
2
2
C
C
Y2
Y2
2
2
7
7
4
4
1
1
TB1
TB1
CHECK
CHECK
------
------
CHECK INPUT POWER
CHECK INPUT POWER
CHECK FUSE ON CONTROL
CHECK FUSE ON CONTROL
REPLACE CONTROL
REPLACE CONTROL
GAS FLOW
GAS FLOW
GAS PRESSURE
GAS PRESSURE
GAS VALVE
GAS VALVE
FLAME SENSOR
FLAME SENSOR
FLAME ROLLOUT
FLAME ROLLOUT
BAD SWITCH
BAD SWITCH
AUX. LIMIT OPEN
AUX. LIMIT OPEN
CHECK
CHECK
PRESSURE SWITCH
PRESSURE SWITCH
CHECK
CHECK
PRESSURE SWITCH
PRESSURE SWITCH
MAIN LIMIT OPEN
MAIN LIMIT OPEN
BAD SWITCH
BAD SWITCH
STICKING GAS VALVE
STICKING GAS VALVE
3 MIN. COMP.
3 MIN. COMP.
ANTI-CYCLE TIMER
ANTI-CYCLE TIMER
www.goodmanmfg.com
-p
460/575 B
hree
hase
COMPONENT LEGEND
COMPONENT LEGEND
ALS
ALS
AUXILLARY LIMIT SWITCH
AUXILLARY LIMIT SWITCH
BC
BC
BLOWER CONTACTOR
BLOWER CONTACTOR
CCH
CCH
CRANK CASE HEATER
CRANK CASE HEATER
CCHR
CCHR
CRANK CASE HEATER RELAY
CRANK CASE HEATER RELAY
COMP
COMP
COMPRESSOR
COMPRESSOR
CM
CM
CONDENSER MOTOR
CONDENSER MOTOR
CC
CC
COMPRESSOR CONTACTOR
COMPRESSOR CONTACTOR
EM
EM
EVAPORATOR MOTOR
EVAPORATOR MOTOR
F
F
FUSE
FUSE
FC
FC
FAN CAPACITOR
FAN CAPACITOR
FS
FS
FLAME SENSOR
FLAME SENSOR
GND
GND
EQUIPMENT GROUND
EQUIPMENT GROUND
GV
GV
GAS VALVE
GAS VALVE
HPS
HPS
HIGH PRESSURE SWITCH
HIGH PRESSURE SWITCH
IBR
IBR
INDOOR BLOWER RELAY
INDOOR BLOWER RELAY
IIC
IIC
INTEGRATED IGNITION CONTROL
INTEGRATED IGNITION CONTROL
IGN
IGN
IGNITOR
IGNITOR
LPS
LPS
LOW PRESSURE SWITCH
LOW PRESSURE SWITCH
LS
LS
LIMIT SWITCH
LIMIT SWITCH
PLF
PLF
FEMALE PLUG/CONNECTOR
FEMALE PLUG/CONNECTOR
PS
PS
PRESSURE SWITCH
PRESSURE SWITCH
RS
RS
ROLLOUT SWITCH
ROLLOUT SWITCH
TB1
TB1
TERMINAL BLOCK (24V SIGNAL)
TERMINAL BLOCK (24V SIGNAL)
TB2
TB2
TERMINAL BLOCK (L1)
TERMINAL BLOCK (L1)
TR
TR
TRANSFORMER
TRANSFORMER
VM
VM
VENT MOTOR
VENT MOTOR
VMR
VMR
VENT MOTOR RELAY
VENT MOTOR RELAY
NOTES
NOTES
1. REPLACEMENT WIRE MUST BE THE SAME
1. REPLACEMENT WIRE MUST BE THE SAME
SIZE AND TYPE OF INSULATION AS ORIGINAL.
SIZE AND TYPE OF INSULATION AS ORIGINAL.
(USE COPPER CONDUCTOR ONLY).
(USE COPPER CONDUCTOR ONLY).
2
2. ACCESSORY ECONOMIZER PLUG ADJACENT
2
2. ACCESSORY ECONOMIZER PLUG ADJACENT
TO BLOWER HOUSING IN RETURN AIR
TO BLOWER HOUSING IN RETURN AIR
COMPARTMENT. REMOVE MALE PLUG AND
COMPARTMENT. REMOVE MALE PLUG AND
ATTACH FEMALE PLUG TO THE ECONOMIZER
ATTACH FEMALE PLUG TO THE ECONOMIZER
ACCESSORY.
ACCESSORY.
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.
3
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.
3
4
4
4. USE COPPER CONDUCTORS ONLY.
4. USE COPPER CONDUCTORS ONLY.
USE NEC CLASS 2 WIRE.
USE NEC CLASS 2 WIRE.
5. FOR TWO STAGE OPERATION REMOVE
5. FOR TWO STAGE OPERATION REMOVE
W1 TO W2 WIRE JUMPER.
W1 TO W2 WIRE JUMPER.
THERMOSTAT
THERMOSTAT
FIELD WIRING
FIELD WIRING
2 STAGE COOLING
2 STAGE COOLING
FACTORY WIRING
FACTORY WIRING
W
W
WH
WH
G
G
GR
GR
LINE VOLTAGE
LINE VOLTAGE
R
R
RD
RD
LOW VOLTAGE
LOW VOLTAGE
Y1
Y1
YL
YL
OPTIONAL
OPTIONAL
Y/Y2
Y/Y2
PK
PK
HIGH VOLTAGE
HIGH VOLTAGE
C
C
BL
BL
OR
OR
O
O
FIELD WIRING
FIELD WIRING
TB1
TB1
HIGH VOLTAGE
HIGH VOLTAGE
NO ECONOMIZER
NO ECONOMIZER
LOW VOLTAGE
LOW VOLTAGE
W
W
WH
WH
G
G
GR
GR
R
R
RD
RD
WIRE CODE
WIRE CODE
Y1
Y1
BK
BK
BLACK
BLACK
Y/Y2
Y/Y2
YL
YL
BL
BL
BLUE
BLUE
BL
BL
C
C
BR
BR
BROWN
BROWN
OR
OR
O
O
GR
GR
GREEN
GREEN
TB1
TB1
OR
OR
ORANGE
ORANGE
PK
PK
PINK
PINK
PU
PU
PURPLE
PURPLE
WITH ECONOMIZER OPTION
WITH ECONOMIZER OPTION
RD
RD
RED
RED
W
W
WH
WH
WH
WH
WHITE
WHITE
G
G
GR
GR
YL
YL
YELLOW
YELLOW
R
R
RD
RD
YL/PK YELLOW WITH
YL/PK YELLOW WITH
Y1
Y1
YL
YL
PINK STRIP
PINK STRIP
Y/Y2
Y/Y2
BL/PK BLUE WITH
BL/PK BLUE WITH
PINK STRIP
PINK STRIP
C
C
BL
BL
O
O
OR
OR
TB1
TB1
0140L00957 REV A
p
s
rodUCT
peCiFiCaTions
d
elT
rive
W
W
G
G
R
R
Y1
Y1
Y2
Y2
C
C
O
O
STAT
STAT
W
W
G
G
R
R
Y2
Y2
C
C
O
O
STAT
STAT
W
W
G
G
R
R
Y
Y
C
C
O
O
STAT
STAT