Download Print this page

Goodman GM9S96 Manual page 4

Single-stage, multi-speed ecm gas furnace up to 96% afue
Hide thumbs Also See for GM9S96:

Advertisement

GC9S96 Specifications
Heating Data
High Fire Input¹
High Fire Output¹
AFUE²
Temperature Rise Range (°F)
Vent Diameter³
No. of Burners
Circulator Blower
Available AC @ 0.5" ESP
Size (D x W)
Horsepower @ 1075 RPM
Speed
Filter Size (in²) (Qty)
Electrical Data
Min. Circuit Ampacity⁴
Max. Overcurrent Device (amps)⁵
Shipping Weight (lbs)
¹
Natural Gas BTU/h
²
DOE AFUE based upon Isolated Combustion System (ICS)
³
Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending
upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must
be 2" or 3" diameter PVC.
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes.
Extensive wire runs will require larger wire sizes.
Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
Gas Service Connection ½" FPT
Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.
For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed
above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
4
GC9S96
GC9S96
0403BN
0603BN
40,000
60,000
38,440
57,660
96
96
25-55
35-65
2" - 3"
2" - 3"
2
3
1.5 - 3
1.5 - 3
11" x 8"
11" x 8"
1/2
1/2
9
9
(2) 10 x 20 or
(2) 10 x 20 or
(1) 16 x 25
(1) 16 x 25
(top return)
(top return)
10.3
10.3
15
15
113
116
www. goodmanmfg.com
GC9S96
GC9S96
0804CN
1005CN
80,000
100,000
76,880
95,000
96
95
40-70
40-70
2" - 3"
2" - 3"
4
5
2.5 - 4
3 - 5
11" x 10"
11" x 10"
3/4
1
9
9
(1) 14 x 20 (bottom)
(2) 10 x 20 or
or
(1) 16 x 25
(1) 20 x 25
(top return)
(top return)
14.1
16.93
15
20
141
144
GC9S96
1205DN
120,000
114,000
95
45-75
3"
6
3 - 5
11" x 11"
1
9
(1) 14 x 20 (bottom)
or
(1) 20 x 25
(top return)
16.93
20
156
SS-GM9S96/GC9S96

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Gc9s96Gm9s96 0403anGm9s96 0603bnGm9s96 0803bnGm9s96 0804cnGm9s96 0805cn ... Show all