Replacing The Fuse; Troubleshooting - Furuno AIS Transponder FA-50 Operator's Manual

Class a ais transponder
Hide thumbs Also See for AIS Transponder FA-50:
Table of Contents

Advertisement

3. MAINTENANCE, TROUBLESHOOTING
3.2

Replacing the Fuse

The fuse (4A) inside the FA-50 protects it from overcurrent and equipment fault. If the
unit cannot be powered, that is, the PWR (power) LED is off, the fuse may have blown.
If this happens, turn off the power to the FA-50, open the body cover and check the
fuse. If the fuse has blown, find out the reason before replacing it. If it blows again after
replacement, contact a FURUNO agent or dealer for advice.
Fuse (4A)
3.3

Troubleshooting

The troubleshooting table below provides typical operating problems and the means
to restore normal operation. If you cannot restore normal operation, do not open the
shield cover; there are no user serviceable parts inside the transponder.
Symptom
Transponder cannot
be powered.
Cannot transmit/re-
ceive
The message is sent
to wrong ship.
No position data
3-2
Part
FGMB 125V 4A PBF
WARNING
Use the proper fuse.
Use of a wrong fuse can result in damage to the
equipment and cause fire.
Fuse inside the transponder
may have blown.
• VHF antenna cable connec-
tion may haveloosened.
• Antenna or its cabling may be
damaged.
• Rx channel setting is wrong.
Setting of transmission is not
correct.
• GPS antenna may be dam-
aged.
• GPS antenna cable may be
damaged.
Type
Problem
Code No.
000-157-482-10
Remedy
Replace the fuse.
• Check if the cable is firmly
connected.
• Check the antenna and its
cabling for damage.
• Confirm the channel set-
ting.
Confirm MMSI.
• Change the GPS anten-
na.
• Check if the cable is firmly
fastened. If the cable has
damage, change it.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents