7.2

XTE Alarm, Border Alarm

The XTE (cross-track error) alarm warns you when own ship is off its intended course.
The Border alarm alerts you when own ship is nearing an area which you do not want to
approach.
Intended
course
Own ship's position
1. Press [MENU], [1], [1], [0], [0], [2], [2] to display the Alarm Set menu.
2. Press the [3] key to choose XTE or Border.
3. Press the [ENTER/SELECT] key.
4. Key in alarm range (0.001-9.999). (To cancel input, press the [CANCEL/CLEAR] key.)
5. Press the [ENTER/SELECT] key.
6. Press the [MENU] key to finish.
To disable the XTE alarm or Border alarm, choose Off at step 2 in the above procedure.
Own ship
position
: Alarm
XTE ALARM
BORDER ALARM
XTE alarm, border alarm concept
Destination
Alarm
waypoint
setting
Setting line
Alarm
setting
: Alarm range
7. ALARMS