Statement 1:
DANGER
1. Refer to the documentation that comes with your rack cabinet for additional
2. Install the Rack PDU 3 on the vertical mounting plate 2 with four M3x5
150
Hardware Maintenance Manual: IBM PC Server/Enterprise Racks Types 9306, 9308
Electrical current from power, telephone, and communication cables is
hazardous. To avoid a shock hazard:
v Do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical
storm.
v Connect all power cords to a properly wired and grounded electrical
outlet.
v Connect to properly wired outlets any equipment that will be attached to
this product.
v When possible, use one hand only to connect or disconnect signal
cables.
v Never turn on any equipment when there is evidence of fire, water, or
structural damage.
v Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless
instructed otherwise in the installation and configuration procedures.
v Connect and disconnect cables as described in the following table when
installing, moving, or opening covers on this product or attached
devices.
To connect:
1. Turn everything OFF.
2. First, attach all cables to devices.
3. Attach signal cables to connectors.
4. Attach power cords to outlet.
5. Turn device ON.
information.
Note: Removing the rack doors and side panels might make your Rack PDU
installation easier.
screws 1 that come with this option. Make sure that the countersink holes in
the vertical mounting plate are facing away from the device.
Note: Align the Rack PDU to one end or the other of the vertical mounting
plate to leave room for a second device.
To disconnect:
1. Turn everything OFF.
2. First, remove power cords from outlet.
3. Remove signal cables from connectors.
4. Remove all cables from devices.