Completing Sanitize On A Device Using The Ocgui - Western Digital OpenFlex F3 Series Instruction Manual

Hide thumbs Also See for OpenFlex F3 Series:
Table of Contents

Advertisement

EcoDesign Disclosures
Step 18 : Select options for the number of pools and the secure erase option and click Initialize.
The device secure erase will be executed.
1.3.2   Completing Sanitize on a Device Using the OCGUI
This task provides steps that should be followed to complete the sanitizing procedure on a storage device
using the OCGUI. This feature provides two options for securely sanitizing the storage device:
• Block Erase will delete the mapping table and erase all of the blocks that have been written to the
device.
• Cryptographic Erase (fastest option) will delete the encryption key which will result in making the
data unrecoverable.
Step 1 : Enter a valid username and password, and click the Login button:
The system dashboard appears:
Note: The default username/password is
1. EU EcoDesign Compliance
1.3 Secure Erase and Sanitize
/
.
admin
admin
7