With the "Communication" submodule, configurations can be transferred from or to the
communications module, and a status query can be performed via the communications
module.
Table 6- 3
Parameters of the parameter group "Module parameters" of the connected readers
Parameter
User mode
MOBY mode
Transmission
speed
Diagnostic
messages
SIMATIC RF166C
Operating Instructions, 03/2022, C79000-G8976-C578-02
Parameter value
Ident profile/RFID
standard profile
FB 45
RF200/RF300/RF600;
MV400/MV500; MOBY
U/D normal addr.
19.2 kBd
57.6 kBd
115.2 kBd
921.6 kBd
None
Hard errors
Hard/soft errors
Default value
Description
Ident profile/RFID
With this parameter, you select the block:
standard profile
RF200/RF300/RF600
With this parameter, you set the mode of the
; MV400/MV500;
communication module.
MOBY U/D normal
addr.
Normal addressing: The transponder is
addressed with physical addresses.
115.2 kBd
With this parameter, you set the data
transmission speed between the
communication module and reader.
When an optical reader is connected: The
transmission speed selected here must match
the transmission speed selected for the reader.
None
With this parameter, you determine the extent
to which the reader-related diagnostic interrupt
messages are to be reported.
6.2 Configuration via PROFIBUS (STEP 7)
Ident profile/RFID standard profile:
Single tag / multitag operation. The program
block for the Ident profile is used in the
controller.
FB 45:
Single tag mode. FB 45 is used in the
controller.
Only in connection with an S7-300
controller.
RF200/RF300/RF600; MV400/500; MOBY U/D
normal addr.
None:
No alarms are generated.
Hard errors:
Critical hardware errors/faults are reported
by the S7 diagnostics.
Hard/soft errors:
Critical hardware faults and errors occurring
when processing commands are reported by
the S7 diagnostics.
Configuring
53