Connection Descriptions

5 Connection Descriptions
Table 5-1
shows the test points populated on the board as well as the signal connectors.
Connector and Test Point
J1 to J4
J5, TP1
J6
J7, J22, TP4, TP5, TP6
TP7
J20, TP3
J21, TP2
TP8
TP9
TP10
TP11
Table 5-2
shows the relevant configuration jumpers of the TPS272C45EVM as well as the associated values.
Please refer to the TPS272C45 data sheet for detailed information on each pin's functionality.
Jumper
J8
J9
J10
J11
J12
J13
J14, J15
J16
J17
J18
J19
J23
6
TPS272C45 Evaluation Module

Table 5-1. Connections and Test Points

BOOST-XL headers to connect to Texas Instruments LaunchPad Ecosystem
Supply voltage
Supply rail for Vdd (A, C, D version of the TPS272C45 only)
Ground connections
Current sense output (SNS)
Output voltage 2 (VOUT2)
Output voltage 1 (VOUT1)
Enable for VOUT1 (EN1)
Enable for VOUT2 (EN2)
Shared fault line (FAULT)
IC Ground (IC_GND)

Table 5-2. Jumper Configurations

Controls EN1 and enables, disables VOUT1
Controls EN1 and enables, disables VOUT2
Sets DIA_EN and enables, disables diagnostics
Controls the SEL pin to set which diagnostics are reported by the SNS pin
Sets the functionality of the device during fault conditions via the LATCH pin
Enables, disables the on-board 3.3-V LDO. Must be set to top position (marked on silk screen as 3.3-V
LDO) to allow J8 to J12 to be high.
Controls which resistance value that is going into ILIM1. Only populate either J14 or J15 (not both) at a
time. If J14 is populated a 10-kΩ value is used and if J15 is used a 4.99-kΩ value is used for ILIM1. If
controlling from a from a microcontroller do not populate J14 or J15.
Controls whether or not to use the diode/resistor ground network for reverse current blocking. Populate
jumper to bypass ground network.
Selects if Vdd is being supplied by the BoosterPack or the on-board LDO. Do no populate if being supplied
externally through J6.
Controls if the FAULT line is being pulled up by the BoosterPack or the on-board LDO
Connects the BoosterPack 3.3-V rail to the on-board LDO's 3.3-V output giving the ability to power the
connected LaunchPad from the LDO.
Configures pin 18 to be connected to ILIMD in A, B, C version or FLT1 in D version
Copyright © 2021 Texas Instruments Incorporated
Description
Function/Settings
SLVUBV4A – DECEMBER 2020 – REVISED DECEMBER 2021
www.ti.com
Submit Document Feedback